SHUQUALAK, MS —
OSHA Inspection: SHUQUALAK LUMBER COMPANY, INC. PLANER MILL DIVISION
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of SHUQUALAK LUMBER COMPANY, INC. PLANER MILL DIVISION in 87 OAK ST., SHUQUALAK, MS 39361 (NAICS 321912). OSHA activity number 344671136.
Where did this inspection happen?
- Establishment
- SHUQUALAK LUMBER COMPANY, INC. PLANER MILL DIVISION
- Site address
- 87 OAK ST.
- City
- SHUQUALAK
- State
- MS
- ZIP
- 39361
- Mailing
- P.O BOX 68, SHUQUALAK, MS 39361
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321912
- Employees
- 120
- Ownership type
- A
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $13494.00 · Current $13494.00
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Public Law 91-596, the Occupational Safety and Health Act of 1970, Section 5(a)(1): The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or are likely to cause death or serious physical harm to his employees, in that employees were exposed to a struck-by hazards. a) Planer Mill - On or about March 4, 2020 employees working or walking in in the planer mill yard were exposed to struck-by hazards where equipment such as, but not limited to, forklifts were being operated.
Recent events (2)
- — I (S) $13494
- — Z (S) $13494
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $5725.00 · Current $5725.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. Maintenance - On or About March 4, 2020 a periodic inspection of the lockout/tagout procedures was not conducted at least annually.
Recent events (2)
- — I (S) $5725
- — Z (S) $5725
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $7634.00 · Current $7634.00
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Facility - On or about March 4, 2020 the forklift operators were not recertified at least once every three years.
Recent events (2)
- — I (S) $7634
- — Z (S) $7634
1910.22 A01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition. a. Maintenance Shop - On or about March 17, 2020 in the maintenance shop, the floor was cluttered with old parts and other items that were stored haphazardly, exposing employees to a trip hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 B03 II C 3
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(b)(3)(ii)(C)(3): 29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug found damaged or defective was used before being repaired: a. Breakroom - On or about March 17, 2020 a refrigerator in the breakroom was plugged into an extension cord that had damage to the outer insulation at the female plug.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:. a. Breakroom - On or about March 17, 2020 a refrigerator in the breakroom that was plugged into an extension cord used as permanent wiring.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws. a. Breakroom - On or about March 17, 2020 a refrigerator in the breakroom was plugged into an extension cord that did not have strain relief at the female plug.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 321912)
PINEOLA, NC—2026-07-07
161497 - C.L. LOVEN LUMBER CO., INC.
PIERZ, MN—2026-07-06
111530 - RICH PRAIRIE CUSTOM WOODS LLC
WHITE CITY, OR—2026-06-18
317744567 - WESTERN VALLEY CUTSTOCK INC
BUCKHANNON, WV—2026-06-10
AFP LOGS AND LUMBER INC.
BYRON CENTER, MI—2026-06-04
NORTHWEST HARDWOODS INC
More inspections in MS
LAUREL, MS—2026-07-01
THERMO-KOOL
HORN LAKE, MS—2026-07-01
NEWLY WEDS FOODS, INC.
GAUTIER, MS—2026-07-01
DOUBLE R GAUTIER, LLC
OLIVE BRANCH, MS—2026-06-30
HYVE SOLUTIONS
GAUTIER, MS—2026-06-30
STEVE WILSON ENTERPRISE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344671136.