Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SHUQUALAK LUMBER COMPANY, INC. PLANER MILL DIVISION

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SHUQUALAK LUMBER COMPANY, INC. PLANER MILL DIVISION in 87 OAK ST., SHUQUALAK, MS 39361 (NAICS 321912). OSHA activity number 344671136.

Watch Shuqualak Lumber Company, INC. Planer Mill Division — free Get an email when a new federal OSHA severe-injury report for Shuqualak Lumber Company, INC. Planer Mill Division is published. One employer, no account, unsubscribe in one click.
Site address
87 OAK ST.
City
SHUQUALAK
State
MS
ZIP
39361
Mailing
P.O BOX 68, SHUQUALAK, MS 39361
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321912
Employees
120
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 48 exposed
Issued
Abate by
Penalty
Initial $13494.00 · Current $13494.00
OSH ACT of 1970 Section (5)(a)(1): Public Law 91-596, the Occupational Safety and Health Act of 1970, Section 5(a)(1): The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or are likely to cause death or serious physical harm to his employees, in that employees were exposed to a struck-by hazards.  a) Planer Mill - On or about March 4, 2020 employees working or walking in in the planer mill yard were exposed to struck-by hazards where equipment such as, but not limited to, forklifts were being operated.
Recent events (2)
  • — I (S) $13494
  • — Z (S) $13494

1910.147 C06 I

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $5725.00 · Current $5725.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a. Maintenance - On or About March 4, 2020 a periodic inspection of the lockout/tagout procedures was not conducted at least annually.
Recent events (2)
  • — I (S) $5725
  • — Z (S) $5725

1910.178 L04 III

Serious Gravity 5 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $7634.00 · Current $7634.00
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  a) Facility - On or about March 4, 2020 the forklift operators were not recertified at least once every three years.
Recent events (2)
  • — I (S) $7634
  • — Z (S) $7634

1910.22 A01

Other-than-serious 1 instance 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition.  a. Maintenance Shop - On or about March 17, 2020 in the maintenance shop, the floor was cluttered with old parts and other items that were stored haphazardly, exposing employees to a trip hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 B03 II C 3

Other-than-serious 1 instance 40 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(b)(3)(ii)(C)(3): 29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug found damaged or defective was used before being repaired:  a. Breakroom - On or about March 17, 2020 a refrigerator in the breakroom was plugged into an extension cord that had damage to the outer insulation at the female plug.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 40 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:.  a.  Breakroom - On or about March 17, 2020 a refrigerator in the breakroom that was plugged into an extension cord used as permanent wiring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 40 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws.  a. Breakroom - On or about March 17, 2020 a refrigerator in the breakroom was plugged into an extension cord that did not have strain relief at the female plug.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344671136.