Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: SIMPSON STRONG-TIE COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SIMPSON STRONG-TIE COMPANY, INC. in 2600 INTERNATIONAL STREET, COLUMBUS, OH 43228 (NAICS 332312). OSHA activity number 344680566.

Watch Simpson Strong-Tie Company, INC. — free Get an email when a new federal OSHA severe-injury report for Simpson Strong-Tie Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2600 INTERNATIONAL STREET
City
COLUMBUS
State
OH
ZIP
43228
Mailing
2600 INTERNATIONAL STREET, COLUMBUS, OH 43228
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
314
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Other-than-serious 25 instances 250 exposed
Issued
Abate by
Penalty
Initial $9639.00 · Current $8193.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   a. On or about March 9, 2020, the employer did not ensure that lockout/tagout procedures were fully documented for Minster presses 60A and 60B for employees to utilize during maintenance and servicing activities.
Recent events (2)
  • — I (O) $8193.15
  • — Z (S) $9639

1910.147 D

Deleted Serious Gravity 5 2 instances 250 exposed
Issued
Abate by
Penalty
Initial $9639.00 · Current $0.00 Reduced
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence as required by 29 CFR 1910.147(d)(1) through (d)(6):  a. On or about March 9, 2020, employees were performing setup work on the MAP 115, 100 ton, power press. The employer did not ensure that energy control application steps were implemented as the press was not shut down to perform the work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i), and verification of isolation [(d)(6)], were not implemented to protect the employees from machine servicing hazards.     b. On or about March 9, 2020, and at times thereto, employees were performing service and maintenance work within the tool and die block area without performing lockout/tagout. The employer relied on the control circuit of the die block interlock in lieu of performing machine energy isolation. The employer did not ensure that energy control application steps were implemented as the press was not shut down to perform the work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i), and verification of isolation [(d)(6)], were not implemented to protect the employees from machine servicing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9639

View SIMPSON STRONG-TIE COMPANY, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344680566.