OSHA Inspection: DEWINE MECHANICAL INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEWINE MECHANICAL INC. in 1267 E. 32ND AVE, COLUMBUS, NE 68601 (NAICS 332312). OSHA activity number 344689898.

Watch Dewine Mechanical INC. — free Get an email when a new federal OSHA severe-injury report for Dewine Mechanical INC. is published. One employer, no account, unsubscribe in one click.
Site address
1267 E. 32ND AVE
City
COLUMBUS
State
NE
ZIP
68601
Mailing
1267 E. 32ND AVE, COLUMBUS, NE 68601
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
15
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $4588.00 · Current $3212.00 Reduced
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Employees are exposed to the hazard of a mechanical rotating part.  This violation was most recently documented on March 6, 2020 at 1267 E. 32nd Ave., Columbus, Nebraska. The employer failed to ensure the Jet drill press was being used with a guard.
Recent events (2)
  • — I (S) $3211.6
  • — Z (S) $4588

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $4588.00 · Current $3212.00 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:                                                                 The employer is failing ensure that employees are protected from electrical hazards. This was most recently documented on March 6, 2020 at 1267 E. 32nd Ave., Columbus, Nebraska.  The employer failed to ensure that a flexible cord on the Uni-Hydro iron worker foot pedal had strain relief.
Recent events (2)
  • — I (S) $3211.6
  • — Z (S) $4588

View DEWINE MECHANICAL INC.'s full OSHA safety record →