OSHA Inspection: JAMES PLACE, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAMES PLACE, INC in 4885 CHESTNUT RIDGE ROAD, AMHERST, NY 14228 (NAICS 236116). OSHA activity number 344694336.

Watch James Place, INC — free Get an email when a new federal OSHA severe-injury report for James Place, INC is published. One employer, no account, unsubscribe in one click.
Establishment
JAMES PLACE, INC
Site address
4885 CHESTNUT RIDGE ROAD
City
AMHERST
State
NY
ZIP
14228
Mailing
2217 SWEET HOME ROAD, AMHERST, NY 14228
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.150 C01 I

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1253.00 · Current $940.00 Reduced
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof:   a) On or about 3/9/20, at the site of Amherst, NY. A two-story wood frame building, that was under construction with approximately 10,000 total square feet, was not provided with fire extinguishers.   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $939.75
  • — Z (S) $1253

1926.405 E01

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures:   a) On or about 3/9/20, at the yard area of the site, Amherst, NY. Receptacle outlets, installed by the outdoor electric panel area, lacked the weather-resistant covers to prevent moisture or water from entering and accumulating within the receptacles.  NO ABATEMENT CERTIFICATION REQUIRED