WASHINGTON, DC —
OSHA Inspection: JOSEPH ALAN WHITE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOSEPH ALAN WHITE in 3411 QUEBEC STREET NW, WASHINGTON, DC 20016 (NAICS 238160). OSHA activity number 344699483.
Where did this inspection happen?
- Establishment
- JOSEPH ALAN WHITE
- Site address
- 3411 QUEBEC STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 2401 DOUBS CT, ADAMSTOWN, MD 21710
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 G01 I
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2025.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about March 16, 2020; roof area; employees working on a ladder-jack scaffold system were exposed to an estimated 19-foot fall hazard while conducting roofing work without fall protection. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2025
- — Z (S) $4048
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2025.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about March 16, 2020; roof area; employees were not provided fall protection while installing shingles on a steep residential roof exposing them to an estimated 25-foot fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2025
- — Z (S) $4048
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $2949.00 · Current $1850.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about March 16, 2020; roof; the ladder used to access the ladder-jack scaffold system had the sides rails extended 18-inches above the platform exposing them to a 19-foot fall hazard while accessing the ladder or working platform. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $1850
- — Z (S) $2949
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about March 16, 2020; throughout the site; the employer had not certified the fall protection training for employees exposed to an estimated 25-foot fall hazard while conducting roofing work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in DC
WASHINGTON, DC—2026-06-30
U.S. DEPARTMENT OF AGRICULTURE
WASHINGTON, DC—2026-06-16
MACY'S
WASHINGTON, DC—2026-06-02
RIGO MULTISERVICES
WASHINGTON, DC—2026-06-02
DDC CPL LLC
WASHINGTON, DC—2026-06-02
DDC CPL LLC
Source