JASPER, GA —
OSHA Inspection: STANDRIDGE COLOR CORP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STANDRIDGE COLOR CORP in 455 HOOD ROAD, JASPER, GA 30143 (NAICS 424950). OSHA activity number 344702261.
Where did this inspection happen?
- Establishment
- STANDRIDGE COLOR CORP
- Site address
- 455 HOOD ROAD
- City
- JASPER
- State
- GA
- ZIP
- 30143
- Mailing
- 455 HOOD ROAD, JASPER, GA 30143
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424950
- Employees
- 7
- Ownership type
- A
Citations
15 citations on file for this inspection.
1910.22 A01
- Issued
- Penalty
- Initial $4596.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All walking-working surfaces were not kept in a clean, orderly, and sanitary condition: On or about 3/17/2020 at the mezzanine area, workers were exposed to slip and fall hazards of up to seven feet to the lower surface where the walking/working surfaces were not maintained in a clean condition where mixing materials such as but not limited to calcium were observed filling in the non-skid treads and surfaces of equipment and areas including but not limited to: a. Werner eight foot tall step ladder; b. Werner six foot tall step ladder; c. Premier platform (Scissors) lift; d. stairs accessing and egressing from the mezzanine; and e. Mezzanine flooring separating creating a half inch tripping hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $4596
1910.28 B01 I
- Issued
- Penalty
- Initial $9012.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): (1) Unprotected sides and edges. (i) Except as provided elsewhere in this section, the employer must ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the following: [A]Guardrail systems; [B]Safety net systems; [C]or Personal fall protection systems, such as personal fall arrest, travel restraint, or positioning systems. On or about 3/17/2020 at the railcar filling site, the employer failed to ensure that workers performing connecting and disconnecting of the finished product filling hoses were protected against 15-feet eight-inch fall hazards, on the left side of the railcars where there was no anchor point provided.
Recent events (2)
- — I (S) $5000
- — Z (S) $9012
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $9012.00 · Current $6500.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about 3/17/2020 throughout the facility, where the employer failed to ensure that workers performing maintenance tasks such as but not limited to gearbox changes, were not exposed to hazards such as but not limited to caught-in, struck-by, and amputations where specific procedures were not utilized on equipment such as but not limited to line 1 which consists of the extruder and mixer assemblies.
Recent events (2)
- — I (S) $6500
- — Z (S) $9012
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about 3/17/2020 throughout the facility, workers expected to lockout machines and equipment were exposed to struck-by and amputation hazards where the employer failed to include all required steps and information in the specific procedures to include but not limited to: a. Affected employees shall be notified of lockout and reenergization; b. Type of energy sources; c. Magnitude of all energy sources; and d. Release of stored residual energy.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 C02 I
- Issued
- Penalty
- Initial $9012.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about 3/17/2020 on the production floor, operators working at or walking by the production lines including but not limited to line two were exposed to caught in and amputation hazards where the employer failed to ensure that all horizontal rotating shafts were protected at: a. side stuffer - four-inch, keyed shaft, four inch wide X ten inch tall opening, 48-inches above the walking working surface; b. side stuffer - four-inch, keyed shaft, four inch wide X ten inch tall opening, 48-inches above the walking working surface; c. rotor (SCC ACC #0156, 8" SLCM) - fully exposed four-inch, keyed shaft, 41-inches above the walking working surface; d. rotor (SCC ACC #0156, 8" SLCM) - fully exposed four-inch, keyed shaft, 50-inches above the walking working surface; e. WEG gearbox - two-inch, keyed rotating shaft - two inch opening, 48-inches above the walking working surface; f. WEG gearbox - four-inch, keyed rotating shaft - four inch opening, 48-inches above the walking working surface; g. four inch, keyed rotating shaft, seven and one half inch opening, 48-inches above the walking working surface. h. vent stuffer, four-inch unguarded vertical shaft was 75-inches (six-foot three-inches) off of the walking working surface.
Recent events (2)
- — I (S) $6000
- — Z (S) $9012
1910.253 B02 IV
- Issued
- Penalty
- Initial $5408.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: On or about 3/17/2020, workers walking in and around the cylinder storage area were exposed to smoke inhalation and thermal burn hazards where the secured acetylene cylinder was stored without a valve cap.
Recent events (2)
- — I (S) $0
- — Z (S) $5408
1910.253 B04 III
- Issued
- Penalty
- Initial $0.00 · Current $3500.00
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: On or about 2/14/2019, inside the roll-up door, next to the workbench, at the cylinder storage area 20-inches inside the door, vehicles entering and exiting, workers walking by or receiving materials from the area where oxygen and acetylene cylinders were stored within 1-foot of each other were exposed to smoke inhalation and thermal burn hazards.
Recent events (2)
- — I (S) $3500
- — Z (S) $0
1910.303 G02 I
- Issued
- Penalty
- Initial $5408.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about 3/17/2020, on the production floor by line 1, workers walking by or working at the toolbox adjacent to the exposed 110 V electrical outlet were exposed to shock hazards where the metallic outlet box was not effectively closed due to damage, exposing the live electrical components inside.
Recent events (2)
- — I (S) $2500
- — Z (S) $5408
1910.1200 E01 I
- Issued
- Penalty
- Initial $5408.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet. On or about 3/17/2020, at 455 Hood Road, Jasper, GA, where the employer failed to maintain a list for all chemicals they have on hand to include but not limited to: a. Propane; b. Lubricating Oil; c. Helium; d. Nitrogen; e. Oxygen; f. Acetylene; and g. Gasoline.
Recent events (2)
- — I (O) $1500
- — Z (S) $5408
1910.1200 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: On or about 3/17/2020, at 455 Hood Road, Jasper, GA, where the employer failed to maintain Safety Data Sheets for all chemicals they have on hand to include but not limited to: a. Propane; b. Lubricating Oil; c. Helium; d. Nitrogen; e. Oxygen; f. Acetylene; and g. Gasoline.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about 3/17/2020, at 455 Hood Road, Jasper, GA, where the employer failed to provide effective chemical training to all employees on components including but not limited to: a. Safety Data Sheets and the information contained within them; b. Pictograms and the meaning of each.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.134 C02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: On or about 3/17/2020, at 455 Hood Road Jasper, GA. where the employer failed to provide the Appendix "D" to workers provided N95 masks exposing them to inhalation hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about 3/17/20, at the roll-up door near the cylinder storage and maintenance workbench area, where workers were expected to fight small fires the employer failed to ensure that the portable fire extinguisher was not blocked, exposing them to smoke inhalation and burn hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: On or about 3/17/20, throughout the plant in locations including but not limited to below the mezzanine and at the maintenance workbench areas, where the employer failed to ensure that the portable fire extinguisher were inspected monthly, where workers were expected to fight small fires.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B07 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. On or about 3/17/2020 at line #1 shaker, the employer failed to ensure that all knockouts were in place exposing workers performing lockout or working in the area to 440 V electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 424950)
SPARKS, NV—2026-07-06
THE PITTSBURGH PAINTS CO.
SPARKS, NV—2026-07-06
THE PITTSBURGH PAINTS CO.
SHIREMANSTOWN, PA—2026-04-16
APPLICATE COMMERCE
COLTON, CA—2026-03-11
CAL- STRIPE, INC.
WALPOLE, NH—2026-03-09
LEN-TEX CORPORATION
More inspections in GA
GREENSBORO, GA—2026-07-16
PURE BEAUTY FARMS, INC.
FOREST PARK, GA—2026-07-16
POLYNT COMPOSITES USA INC.
AUGUSTA, GA—2026-07-16
GF CASTING SOLUTIONS AUGUSTA, LLC
CHAMBLEE, GA—2026-07-16
U.S. DEPARTMENT OF TREASURY
DECATUR, GA—2026-07-15
PALLETS ACQUISITION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344702261.