Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,783,325Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ENVIROQUIP PARTS LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ENVIROQUIP PARTS LLC in 1198 SHATTUCK INDUSTRIAL BLVD, LA FAYETTE, GA 30728 (NAICS 336211). OSHA activity number 344721071.

Watch Enviroquip Parts LLC — free Get an email when a new federal OSHA severe-injury report for Enviroquip Parts LLC is published. One employer, no account, unsubscribe in one click.
Site address
1198 SHATTUCK INDUSTRIAL BLVD
City
LA FAYETTE
State
GA
ZIP
30728
Mailing
1198 SHATTUCK INDUSTRIAL BLVD, LA FAYETTE, GA 30728
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336211
Employees
118
Ownership type
A

2 citations on file for this inspection.

1910.134 H02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5899.00 · Current $3539.00 Reduced
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve:  (a) Paint prep area: On or about April 8th 2020, and at times prior, the employer exposed employees to respiratory hazards in that respirators were not stored to protect them from damage and dust. Two half-mask respirators, an N95 respirator, and a full-mask respirator were observed improperly stored on dusty work stations in the paint prep area.
Recent events (2)
  • — I (S) $3539.4
  • — Z (S) $5899

1910.252 B02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5899.00 · Current $3539.00 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  (a) Tail-gate station: On or about April 8th, 2020, and at times prior, the employer exposed employees to radiation hazards in that, employees who work at the tail-gate station, adjacent to the welding line, are not protected by flameproof screens or shields and are not required to wear appropriate goggles.
Recent events (2)
  • — I (S) $3539.4
  • — Z (S) $5899

View ENVIROQUIP PARTS LLC's full OSHA safety record →