LYNCHBURG, VA —
OSHA Inspection: BWXT NUCLEAR OPERATION GROUP, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of BWXT NUCLEAR OPERATION GROUP, INC. in 1570 MT. ATHOS ROAD, LYNCHBURG, VA 24504 (NAICS 332313). OSHA activity number 344821145.
Where did this inspection happen?
- Establishment
- BWXT NUCLEAR OPERATION GROUP, INC.
- Site address
- 1570 MT. ATHOS ROAD
- City
- LYNCHBURG
- State
- VA
- ZIP
- 24504
- Mailing
- 1570 MT. ATHOS ROAD, LYNCHBURG, VA 24504
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332313
- Employees
- 2350
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.307 G02 I
- Issued
- Abate by
- Penalty
- Initial $13494.00 · Current $13494.00
General-duty citation text
29 CFR 1910.307(g)(2)(i):Locations were not classified depending on the properties of the flammable vapors, liquids, or gases that may be present and the likelihood that a flammable or combustible concentration or quantity is present. a) On or about 06-19-2020, located at BWXT NOG-Lynchburg 1570 Mt. Athos Rd. Lynchburg, VA 24504, the Super Compactor Cell was not classified for flammable hazards where compacting 55 gallon drums of flammable isopropyl alcohol 99% concentration saturated rags was being performed. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $13494
- — C (S) $13494
- — Z (S) $13494
1910.106 E06 I
- Issued
- Abate by
- Penalty
- Initial $134937.00 · Current $134937.00
General-duty citation text
29 CFR 1910.106(e)(6)(i): "General." Adequate precautions were not taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat. On or about 06-19-2020, located at BWXT NOG-Lynchburg 1570 Mt. Athos Rd. Lynchburg, VA 24504, in the Super Compactor Cell, an employee was exposed to a hazardous flammable atmosphere where 99% isopropyl alcohol was allowed to overflow the trough and accumulate on the floor, and the employer did not take adequate precautions to minimize the ignition of flammable vapors such as cleaning up spills promptly, not compacting metal drums, ensuring electrical outlets and wiring were not damaged, and that electrical equipment was appropriate for the location. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (3)
- — F (R) $134937
- — C (W) $134937
- — Z (W) $134937
1910.106 E09 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $134937.00
General-duty citation text
29 CFR 1910.106(e)(9)(i):"General." Maintenance and operating practices were not in accordance with established procedures which will tend to control leakage and prevent the accidental escape of flammable liquids. Spills were not cleaned up promptly. a) On or about 06-19-2020, located at BWXT NOG-Lynchburg 1570 Mt. Athos Rd. Lynchburg, VA 24504, in the Super Compactor Cell, an employee was exposed to flammable hazards from the compacting of 55 gallon drums containing approximately 25 gallons of 99% concentration isopropyl alcohol where the excess was allowed to pool on the floor for extended periods of time near damaged electrical equipment. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employee(s) and their representatives were informed of this abatement.
Recent events (3)
- — F (R) $134937
- — C (W) $0
- — Z (W) $0
More inspections in this industry (NAICS 332313)
TROY, MI—2026-07-08
ALL WELD INC DBA ALL WELDING & FABRICATING CO
TROY, MI—2026-07-08
ALL WELD INC DBA ALL WELDING & FABRICATING CO
METAIRIE, LA—2026-05-29
LIBERTY WELDING & IRON WORKS CO., INC.
JESSUP, MD—2026-05-04
AEROLAB, INC.
JESSUP, MD—2026-04-23
AEROLAB, INC.
More inspections in VA
VIRGINIA BEACH, VA—2026-07-16
GRAND SLAM CAR WASH
KILMARNOCK, VA—2026-07-16
CARR'S TIRE SERVICE
COLLINSVILLE, VA—2026-07-16
ACES, LLC
PORTSMOUTH, VA—2026-07-15
DACS INC
MANASSAS, VA—2026-07-15
VAFMC LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344821145.