OSHA Inspection: DJ MAINTENANCE AND CONSTRUCTION, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DJ MAINTENANCE AND CONSTRUCTION, LLC in 2476 CHANNEL DR, LITTLETON, CO 80129 (NAICS 238350). OSHA activity number 344821541.

Watch DJ Maintenance AND Construction, LLC — free Get an email when a new federal OSHA severe-injury report for DJ Maintenance AND Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2476 CHANNEL DR
City
LITTLETON
State
CO
ZIP
80129
Mailing
35163 EAST 10TH DRIVE, WATKINS, CO 80137
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
6
Ownership type
A

6 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3856.00 · Current $3856.00
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  (a) On or about July 6, 2020, and at times prior, DJ Maintenance and Construction, LLC., did not ensure that a written respiratory protection program with worksite specific procedures was established and implemented for required respirator use. Employees were required to use 3M half-face respirator provided by the employer.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $3856

1910.134 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) On or about July 6, 2020, and at times prior, DJ Maintenance and Construction, LLC., did not ensure that a medical evaluation was provided to determine the employee's ability to use a respirator. Employees were not provided with a medical evaluation prior to using a 3M half-face respirator provided by the employer.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employees using a tight-fitting facepiece respirator were not annually fit tested:   (a) On or about July 6, 2020, and at times prior, DJ Maintenance and Construction, LLC., did not ensure that employees using tight-fitting facepiece respirators were annually fit tested. Employees were not fit tested prior to using a 3M half-face respirator provided by the employer.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $0

1910.134 K03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:   (a) On or about July 6, 2020, and at times prior, DJ Maintenance and Construction, LLC., did not ensure that training was provided prior to requiring employees to use a respirator. Employees were not trained prior to using a 3M half-face respirator provided by the employer.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $0

1926.150 C01 VI

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3856.00 · Current $3856.00
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite:  (a) On or about July 6, 2020, and at times prior, DJ Maintenance and Construction, LLC., did not ensure that a fire extinguisher was provided within 50 feet of wherever more than 5 gallons of flammable liquids were being used on the jobsite. Employees were exposed to fire hazards while applying D811-23-S decking adhesive, a category 2 flammable liquid, on a deck at a construction jobsite. There were no fire extinguishers available to the workers.     Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $3856

1926.152 F03

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5398.00 · Current $5398.00
29 CFR 1926.152(f)(3): Flammable liquids were used where there were open flames or other sources of ignition within 50 feet of the operation:  (a) On or about July 6, 2020, and at times prior, DJ Maintenance and Construction, LLC., did not ensure that flammable liquids were not used within 50 feet of an ignition source. Employees were exposed to fire hazards while applying D811-23-S decking adhesive, a category 2 flammable liquid, on a deck at a construction jobsite. A Steinel electric heat gun, a source of ignition, was used within 6 feet of the operation.       Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $5398