Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SIENNA STONE MASTERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SIENNA STONE MASTERS in 825 E. US HIGHWAY 80, FORNEY, TX 75126 (NAICS 238140). OSHA activity number 344827704.

Watch Sienna Stone Masters — free Get an email when a new federal OSHA severe-injury report for Sienna Stone Masters is published. One employer, no account, unsubscribe in one click.
Site address
825 E. US HIGHWAY 80
City
FORNEY
State
TX
ZIP
75126
Mailing
13422 HOOPER DRIVE, HOUSTON, TX 77047
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.451(b)(1)(i): The employer did not ensure that each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.  On or about July 8, 2020 and at times prior to, employees working on a welded frame scaffold were exposed to falls of approximately 13 feet to the ground below.  Scaffolds were not fully planked.
Recent events (1)
  • — Z (S) $4048

1926.451 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.451(e)(1): The employer did not ensure that when scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.  On or about July 8, 2020 and at times prior to, employees working on a welded frame scaffold were exposed to falls of approximately 13 feet to the ground below.  Scaffolds were not equipped with safe access.
Recent events (1)
  • — Z (S) $4048

1926.451 G01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.451(g)(1):  The employer did not ensure that each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part.  On or about July 8, 2020 and at times prior to, employees working on a welded frame scaffold were exposed to falls of approximately 13 feet to the ground below.  Scaffolds were not equipped with a guardrail system.
Recent events (1)
  • — Z (S) $4048

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344827704.