Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PINAR STUCCO, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PINAR STUCCO, INC. in 3800 DEER DR, SARASOTA, FL 34240 (NAICS 238140). OSHA activity number 344858238.

Watch Pinar Stucco, INC. — free Get an email when a new federal OSHA severe-injury report for Pinar Stucco, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PINAR STUCCO, INC.
Site address
3800 DEER DR
City
SARASOTA
State
FL
ZIP
34240
Mailing
900 TEATRO CT, ORLANDO, FL 32807
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2892.00 · Current $2892.00
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)   a. On or about 07/29/2020, at 3800 Deer Drive, Sarasota, FL 34240, employees were exposed to a fall hazard while working from a tubular welded frame scaffold 4 frames high and 7 frames wide, in that, 5 scaffold platforms were not fully planked as required allowing a 12 inch distance to the scaffold upright.
Recent events (1)
  • — Z (S) $2892

1926.451 G01

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $4048.00 · Current $4048.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   a. On or about 07/29/2020, at 3800 Deer Drive, Sarasota, FL 34240, employees were exposed to a fall hazard while working from a tubular welded frame scaffold 4 frames high and 7 frames wide, in that, the scaffold was not provided with guardrails as required. The scaffold top frames (fourth frame) were missing the guardrails at the ends and at 6 other frames, the third frames were missing the guardrails at the ends and at 3 other frames and the second frames were missing the guardrails at the ends and at 3 other frames.
Recent events (1)
  • — Z (S) $4048

1926.452 C02

Serious Gravity 5 28 instances 4 exposed
Issued
Penalty
Initial $2892.00 · Current $2892.00
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:  a. On or about 07/29/2020, at 3800 Deer Drive, Sarasota, FL 34240, employees were exposed to a fall hazard while working from a tubular welded frame scaffold, 4 frames high and 7 frames wide, in that, cross bracing was not used at the side of the scaffold adjacent to the building.
Recent events (1)
  • — Z (S) $2892

1926.20 B01

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.20(b)(1): A safety and health program was not initiated and/or maintained to provide compliance with the general safety and health provisions of the standard:  a. On or about 07/29/2020 at 3800 Deer Drive, Sarasota, FL 34240, the employer did not develop and implement a safety and health program to address the company policy on safety as well as the employer and employee responsibilities.