GROVE CITY, PA —
OSHA Inspection: BLAIR MASONRY INCORPORATED
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BLAIR MASONRY INCORPORATED in 114 SOUTH CENTER STREET, GROVE CITY, PA 16127 (NAICS 238140). OSHA activity number 344880836.
Where did this inspection happen?
- Establishment
- BLAIR MASONRY INCORPORATED
- Site address
- 114 SOUTH CENTER STREET
- City
- GROVE CITY
- State
- PA
- ZIP
- 16127
- Mailing
- 327 BURNS ROAD, SLIPPERY ROCK, PA 16057
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $1735.00 · Current $1215.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs: A) Blair Masonry on or about August 12, 2020 at the address of 114 South Center Street, Grove City, PA: On or about 8/12/2020, the employer did not have a plan or program (e.g. safety/health program) to identify job site hazards which assists employees in maintaining a safe working environment. Such programs would support the employer and employees in identifying and avoiding potential hazards.
Recent events (2)
- — I (S) $1214.5
- — Z (S) $1735
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. A) Blair Masonry on or about August 12, 2020 at the address of 114 South Center Street, Grove City, PA: On or about 8/12/2020, Employees were conducting masonry operations from a tubular welded frame scaffold at heights up to 12-feet above ground level. Employees had not received scaffold safety training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B01 I
- Issued
- Abate by
- Penalty
- Initial $2892.00 · Current $2024.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. A) Blair Masonry on or about August 12, 2020 at the address of 114 South Center Street, Grove City, PA: On or about 8/12/2020, Employees were conducting masonry operations from a tubular welded frame scaffold. A single 2 X 8 board was placed on the scaffold that employees were walking on to access from one scaffold platform to another. The space between the 2 X 8 board and the scaffold unit was at least 12-inches on both sides. The condition exposed employees to a fall hazard of 12-feet.
Recent events (2)
- — I (S) $2024.4
- — Z (S) $2892
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. A) Blair Masonry on or about August 12, 2020 at the address of 114 South Center Street, Grove City, PA: On or about 8/12/2020, employees were conducting masonry operations from a tubular welded frame scaffold Employees were not protected from falls during scaffolding operations. Employees were exposed to a 12 foot fall off the end of the scaffolding platform.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: A) Blair Masonry on or about August 12, 2020 at the address of 114 South Center Street, Grove City, PA: On or about 8/12/2020, employees were conducting masonry operations from a tubular welded frame scaffold. A competent person did not conduct a daily inspections before each work shift.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.