Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NORTH SHORE DRYWALL LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of NORTH SHORE DRYWALL LLC in 231 MAIN ST., EVANSTON, IL 60202 (NAICS 238350). OSHA activity number 344913249.

Watch North Shore Drywall LLC — free Get an email when a new federal OSHA severe-injury report for North Shore Drywall LLC is published. One employer, no account, unsubscribe in one click.
Site address
231 MAIN ST.
City
EVANSTON
State
IL
ZIP
60202
Mailing
69 PARK AVE, LAKE ZURICH, IL 60047
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238350
Employees
4
Ownership type
A

5 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $329.00 · Current $329.00
29 CFR  1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   NORTH SHORE DRYWALL LLC, failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number            Item Number                    Abatement Date  01                                          02a                                         11/25/2020 01                                          02b                                         11/25/2020    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $329

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2313.00 · Current $2313.00
29 CFR 1926.100(a):  Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    a) On September 3, 2020, an employee working on the ground was not wearing a protective helmet where there was a possible danger of head injury from falling objects during carpentry operations.  No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $2313

1926.405 J01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2892.00 · Current $2892.00
29 CFR 1926.405(j)(1)(i):  Fixtures, lamp holders, lamps, rosettes, or receptacles had live parts exposed to employee contact:  a)  On or about September 3, 2020, employees were exposed to electrical hazards while using electrical equipment plugged into an outlet receptacle which was not attached to the outlet box and did not have a faceplate, which exposed live parts.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2892

1926.416 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    a)  On or about September 3, 2020, employees were not protected against contact with energized exposed electrical wiring during carpentry work.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $0

1926.1053 B12

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side rails:  a) On or about September 3, 2020, employees were not protected against accidental contact with energized overhead power lines having a voltage rating of 120/240 volts during carpentry work while working from an aluminum extension ladder.    No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344913249.