CHICAGO, IL —
OSHA Inspection: TIN MAN HEATING & COOLING, INC. DBA DCS MECHANICAL INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TIN MAN HEATING & COOLING, INC. DBA DCS MECHANICAL INC. in 1111 W ADDISON ST, CHICAGO, IL 60613 (NAICS 238220). OSHA activity number 344923008.
Where did this inspection happen?
- Site address
- 1111 W ADDISON ST
- City
- CHICAGO
- State
- IL
- ZIP
- 60613
- Mailing
- 419 RATHBONE AVE, AURORA, IL 60506
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.501 B01
- Issued
- Abate by
- Penalty
- Initial $9446.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about September 10, 2020, employees were exposed to fall hazards of greater than 60 feet while working on the roof of the building. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $6000
- — Z (S) $9446
1926.501 B04 I
- Issued
- Abate by
- Penalty
- Initial $9446.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes: a) On or about September 10, 2020, employees were exposed to falls of approximately 21 feet while working around unprotected floor holes. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $6000
- — Z (S) $9446
1926.502 D06 I
- Issued
- Abate by
- Penalty
- Initial $9446.00 · Current $6000.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(6)(i): A snaphook not designed for such use was engaged directly to webbing, rope or wire rope: a) On or about September 10, 2020, employees were using a personal fall arrest life line that had its locking snaphook engaged back onto the life line rope. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $6000
- — Z (S) $9446
1926.502 D11
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded: a) On or about September 10, 2020, employees were using personal fall arrest life lines that were not protected from being cut or abraded. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D16 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: a) On or about September 10, 2020, employees were using personal fall arrest systems that would allow the employee to free fall greater than 6 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 A01
- Issued
- Penalty
- Initial $6747.00 · Current $4000.00 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) On or about September 10, 2020, employees were exposed to fall hazards and the employer did not provide a training program to recognize fall hazards and the procedures to be followed in order to minimize those hazards. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $4000
- — Z (S) $6747
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $5398.00 · Current $2290.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about September 10, 2020, employees were exposed to fall hazards while using an A-frame ladder without its metal spreaders or locking devices in the open position. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $2289.8
- — Z (S) $5398
More inspections in this industry (NAICS 238220)
LOS ANGELES, CA—2026-07-10
PRIME SC MECHANICAL INC.
RICHARDSVILLE, KY—2026-07-10
69312 - SIEGRIST SERVICE COMPANY LLC
PONCE, PR—2026-07-10
WILLIAM ECHEVARR�A ANDINO
MODESTO, CA—2026-07-09
R.L. FULLER, INC.
SAN JOSE, CA—2026-07-09
ROOTER HERO
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344923008.