OKLAHOMA CITY, OK —
OSHA Inspection: K & M DIRT SERVICES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of K & M DIRT SERVICES, LLC in 11828 S. PENNSYLVANIA, OKLAHOMA CITY, OK 73170 (NAICS 238910). OSHA activity number 344933429.
Where did this inspection happen?
- Establishment
- K & M DIRT SERVICES, LLC
- Site address
- 11828 S. PENNSYLVANIA
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73170
- Mailing
- 4920 SW 134TH ST., OKLAHOMA CITY, OK 73173
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 60
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 F15
- Issued
- Penalty
- Initial $5461.00 · Current $3277.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(15): Ladders were used on scaffolds to increase the working level height of employees; without satisfying the criteria of subparagraphs (i) - (iv) of this paragraph. On or about September 17, 2020 and at times prior thereto, the employer allowed employees to use A-frame ladders on the platform of a scaffold. The ladder was not secured and exposed employees to a fall hazard.
Recent events (2)
- — I (S) $3276.6
- — Z (S) $5461
1926.451 C02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation. On or about September 17, 2020 and at times prior thereto, the employer did not ensure that the base plates were installed on the scaffold end frames. Employees were working from the scaffold and were exposed to a fall hazard. a. The scaffold located on the east side of the front entrance overhang. b. The scaffold located on the west side of the front entrance overhang.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B11
- Issued
- Penalty
- Initial $9557.00 · Current $5734.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems. On or about September 17, 2020 and at times prior thereto, the employer did not ensure that employees, performing roofing activities, were in use of fall protection. This exposed employees to a fall greater than six (6) feet to the ground below.
Recent events (2)
- — I (S) $5734.2
- — Z (S) $9557
1926.1053 B01
- Issued
- Penalty
- Initial $4096.00 · Current $2458.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed and the ladder was not secured. On or about September 17, 2020 and at times prior thereto, at the southwest side of the building near the front entrance, the employer did not ensure that the side rails of a ladder extended at least 3 feet above the landing. The ladder was not secured and exposed employees to a fall hazard.
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
1926.1053 B04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed. On or about September 17, 2020 and at times prior thereto, the employer did not ensure that A-frame ladders were used in a closed position and leaned against the building. This exposed employees to a fall hazard. a. On the southwest scaffold platform, an A-frame ladder was being used in the closed position and leaned against the wall. b. On the southwest scaffold platform, an A-frame ladder, that was in the closed position and leaned against a wall, was being used to access the roof.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238910)
CHARLESTON, WV—2026-07-15
ASTECH CORPORATION
COLLINSVILLE, IL—2026-07-14
L W CONTRACTORS, INC.
STAUNTON, VA—2026-07-14
BRIERY BRANCH LAND MANAGEMENT LLC
BEND, OR—2026-07-14
317744769 - K & E EXCAVATING INC
MIDDLETOWN, NY—2026-07-14
MC STEEL, INC.
More inspections in OK
TULSA, OK—2026-07-15
LA UNION 7 LLC
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
Source