2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ALLIED RESTORATION, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ALLIED RESTORATION, LLC in THE DOME @ SU, 900 IRVING AVENUE, SYRACUSE, NY 13210 (NAICS 238160). OSHA activity number 344937461.

Watch Allied Restoration, LLC — free Get an email when a new federal OSHA severe-injury report for Allied Restoration, LLC is published. One employer, no account, unsubscribe in one click.
Site address
THE DOME @ SU, 900 IRVING AVENUE
City
SYRACUSE
State
NY
ZIP
13210
Mailing
162 GOVERNOR STREET, EAST HARTFORD, CT 06128
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
50
Ownership type
A

4 citations on file for this inspection.

1926.502 D21

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5461.00 · Current $0.00 Reduced
29 CFR  1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:  a) SU Dome roof, north side, west end, on or about 9-15-20 and 9-16-20:  One employee was working on a sloped membrane roof while using a personal fall arrest system (PFAS) that was not inspected prior to each use for wear, damage, and other deterioration and defective components, and defective components were not removed from service.
Recent events (3)
  • — J (S) $0
  • — C (S) $5461
  • — Z (S) $5461

1926.503 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9557.00 · Current $0.00 Reduced
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) SU Dome roof, north side, west end, on or about 9-15-20 and 9-16-20:  Employees were working on a sloped membrane roof, without the specific training necessary for the employees to recognize the hazards associated with falls and their work, exposing the employees to a sliding hazard of upwards of 100 feet and a fall hazard at high speeds of 4 feet 4 inches.  ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM
Recent events (3)
  • — J (S) $0
  • — C (S) $9557
  • — Z (S) $9557

1926.1052 A03

Deleted Serious Gravity 5 1 instance 12 exposed
Issued
Penalty
Initial $5461.00 · Current $0.00 Reduced
29 CFR  1926.1052(a)(3): Variations in riser height or tread depth exceeded 1/4 inch (0.6 cm) within a stairway system:  a) SU Dome, north side, west end, Buck Hoist area, on or about 9-15-20 and 9-16-20:  Employees were accessing a Buck Hoist using a stairway with varying and uneven riser heights, exposing the employees to a fall hazard of 26-1/2 inches.
Recent events (3)
  • — J (S) $0
  • — C (S) $5461
  • — Z (S) $5461

1926.1052 C01 II

Deleted Serious Gravity 5 1 instance 12 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  a) SU Dome, north side, west end, Buck Hoist area, on or about 9-15-20 and 9-16-20:  Employees were accessing a Buck Hoist using a stairway without a stair rail on the open side of the stairs, exposing the employees to a fall hazard of up to 26-1/2 inches.