OSHA Inspection: CAR CRAZY FURNITURE

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CAR CRAZY FURNITURE in 560 SW 1151, MONTROSE, MO 64770 (NAICS 337121). OSHA activity number 344999537.

Watch CAR Crazy Furniture — free Get an email when a new federal OSHA severe-injury report for CAR Crazy Furniture is published. One employer, no account, unsubscribe in one click.
Establishment
CAR CRAZY FURNITURE
Site address
560 SW 1151
City
MONTROSE
State
MO
ZIP
64770
Mailing
505 SW HIGHWAY 52, DEEPWATER, MO 64740
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337121
Employees
2
Ownership type
A

3 citations on file for this inspection.

1910.303 B07 I

Serious Gravity 5 10 instances 2 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $1463.00 Reduced
29 CFR  1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.  At a jobsite located at or near 560 SW 1151, Montrose,  MO, employees were exposed to 120 volts of electrical shock hazards when coverings were missing or broken on electrical outlet and electrical switch boxes.    1) In the main production area, five electrical outlets (120 volts) were missing face plates.  2) In the shipping area, four electrical outlets and/or switches (120 volts) were missing face plates.  One electrical outlet had a damaged face plate that contained a hole.
Recent events (2)
  • — I (S) $1463
  • — Z (S) $2926

1910.305 D02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(d)(2):Panelboard enclosures. Panelboards shall be mounted in cabinets, cutout boxes, or enclosures designed for the purpose and shall be dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons.  At a jobsite located at or near 560 SW 1151, Montrose,  MO, employees were exposed to 240 volts of electrical shock hazards when a circuit breaker was missing the front cover.    1) In the main production area, a circuit breaker box (240 volts) was missing the front cover.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1755.00 · Current $877.00 Reduced
29 CFR  1910.1200(e)(1):Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   At a jobsite located at or near 560 SW 1151, Montrose,  MO, employees were exposed to chemicals including, but not limited to, paints, solvents, clear coat applications, and adhesives.  Hazards from these products include fire hazards, respiratory hazards, and skin contact hazards.  The employer had not developed or implemented a written hazard communication program.
Recent events (2)
  • — I (S) $877
  • — Z (S) $1755