BERLIN, CT —
OSHA Inspection: TOMZ CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TOMZ CORPORATION in 47 EPISCOPAL ROAD, BERLIN, CT 06037 (NAICS 339112). OSHA activity number 345061600.
Where did this inspection happen?
- Establishment
- TOMZ CORPORATION
- Site address
- 47 EPISCOPAL ROAD
- City
- BERLIN
- State
- CT
- ZIP
- 06037
- Mailing
- 47 EPISCOPAL ROAD, BERLIN, CT 06037
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339112
- Employees
- 246
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about December 11, 2020, the employer had not reviewed the lockout/tagout program annually. The last review date was March 13, 2006 .
Recent events (1)
- — Z (O) $0
1910.157 C01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) On or about December 11, 2020 on the second floor, Laser Marking room, a fire extinguisher was found not mounted . b) On or about December 11, 2020 in the first floor Chip room, a fire extinguisher was found not mounted. c) On or about December 11, 2020 on the first floor adjacent to an emergency exit, a fire extinguisher was found not mounted.
Recent events (1)
- — Z (O) $0
1910.303 G01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: On or about December 11, 2020, an electrical panel was found to be obstructed by by a pallet with material on it. Employees were exposed to possible prolonged exposure to electrical sources due to the electric panel box being inaccessible.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 339112)
PEACHTREE CITY, GA—2026-06-11
GERRESHEIMER PEACHTREE CITY (USA), L.P.
MARSHFIELD, MA—2026-06-11
KIRWAN SURGICAL PRODUCTS LLC
HOUSTON, TX—2026-06-11
ALCON LABORATORIES, INC.
OSSEO, MN—2026-05-27
111319 - BOSTON SCIENTIFIC CORPORATION
DRAPER, UT—2026-05-21
EDWARDS LIFESCIENCES, LLC
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345061600.