HASKELL, OK —
OSHA Inspection: CELTIC CABLE CONSTRUCTION LLC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of CELTIC CABLE CONSTRUCTION LLC in 23461 W. 30TH ST. N., HASKELL, OK 74436 (NAICS 238210). OSHA activity number 345084446.
Where did this inspection happen?
- Establishment
- CELTIC CABLE CONSTRUCTION LLC
- Site address
- 23461 W. 30TH ST. N.
- City
- HASKELL
- State
- OK
- ZIP
- 74436
- Mailing
- PO BOX 366, EUFAULA, OK 74432
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 17
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.67 C02 V
- Issued
- Abate by
- Penalty
- Initial $5461.00 · Current $3939.00 Reduced
General-duty citation text
29 CFR 1910.67(c)(2)(v): (v) A personal fall arrest or travel restraint system that meets the requirements in 29 CFR part 1910, subpart I, shall be worn and attached to the boom or basket when working from an aerial lift. On or about January 1, 2021, and at times prior there to, an employee was not wearing personal fall arrest or travel restraint system with lanyard attached to the boom or basket while working from an aerial lift. The employee was exposed to a fall hazard.
Recent events (2)
- — I (S) $3939
- — Z (S) $5461
1910.30 A03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.30(a)(3)(iv): The employer did not train each employee in the correct use of personal fall protection systems and equipment specified in paragraph (a)(1) of this section, including, but not limited to, proper hook-up, anchoring, and tie-off techniques, and methods of equipment inspection and storage, as specified by the manufacturer. On or about January 1, 2021, and at times prior there to, employees were not trained in use of the correct personal fall arrest systems and equipment including but not limited to, proper hook-up, anchoring, tie-off techniques and methods to inspect and store equipment. Employees are exposed to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.268 B07
- Issued
- Abate by
- Penalty
- Initial $5461.00 · Current $5461.00
General-duty citation text
29 CFR 1910.268(b)(7): The employer did not ensure that no employee approached or took any conductive object closer to any electrically energized overhead power lines and parts than prescribed in Table R-2 or in (i) - (iii) of this section: On or about January 1, 2021 and at times prior there to, the employer permitted employees to work in close proximity to energized overhead service lines and equipment. Employees were exposed to electrical shock hazards while performing installation of fiber optic cable line.
Recent events (2)
- — I (S) $5461
- — Z (S) $5461
1910.268 C
- Issued
- Abate by
- Penalty
- Initial $5461.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.268(c): The employer did not provide training in the various precautions and safe practices described in this section and insure that employees do not engage in the activities to which this section applies until such employees have received proper training in the various precautions and safe practices required by this section and did not certify that employees have been trained by preparing a certification record which includes the identity of the person trained, the signature of the employer or the person who conducted the training, and the date the training was completed: On or about January 1, 2021 and at times prior there to, the employer did not provide training in precautions and safe practices nor did the employer certify that employees had been trained. This exposes employees to hazards including but not limited to fall and electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $5461
1904.33 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1904.33(a): The employer did not maintain the OSHA 300 log, the privacy case list, the annual summary and the OSHA 301 Inident Report forms for five (5) years following the end of the calendar year that those records covered. On or about January 1, 2021, and at times prior to, OSHA 300 logs, privacy case list, annual summary and the OSHA 301 Incident Reports were not maintained.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238210)
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
NIAGARA FALLS, NY—2026-07-10
GAINES ELECTRICAL CONTRACTING, INC.
OGDENSBURG, NY—2026-07-10
S & L ELECTRIC, INC.
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
LYNCHBURG, VA—2026-07-09
WHITE ELECTRICAL SERVICES LLC
More inspections in OK
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
EDMOND, OK—2026-06-23
BRICK EXPERTS INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345084446.