Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EZQUIVEL SHEETMETAL LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of EZQUIVEL SHEETMETAL LLC in 3175 STATE HIGHWAY LOOP 534, KERRVILLE, TX 78028 (NAICS 332322). OSHA activity number 345100150.

Watch Ezquivel Sheetmetal LLC — free Get an email when a new federal OSHA severe-injury report for Ezquivel Sheetmetal LLC is published. One employer, no account, unsubscribe in one click.
Site address
3175 STATE HIGHWAY LOOP 534
City
KERRVILLE
State
TX
ZIP
78028
Mailing
18651 CLOVER PATH, PORTER, TX 77365
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
8
Ownership type
A

4 citations on file for this inspection.

1926.403 B02

Serious Gravity 1 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $1755.00 · Current $500.00 Reduced
29 CFR  1926.403(b)(2):Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  On or about January 11, 2021, and at times prior thereto, three extension cords were inter-connected in order to achieve the length needed to supply power to a Seamer Machine, Makita Model DS4000, Serial Number 13958, exposing the employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $500
  • — Z (S) $1755

1926.416 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2341.00 · Current $1500.00 Reduced
29 CFR  1926.416(e)(1): Worn or frayed electric cords or cables were used:  On or about January 11, 2021, employees were using an extension cord, to provide power to a Seamer Machine DS4000 (serial #13958), with the insulation worn down to the inner wiring of the flexible cord, exposing the employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2341

1926.404 F06

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  On or about January 11, 2021, employees were using an extension cord that was missing a ground pin on it's plug that was powering the Seamer Machine, Makita DS4000 (serial# 13958), exposing the employees to an electrical shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.760 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $1500.00 Reduced
29 CFR  1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.  On or about January 11, 2021, and at times prior thereto, 3 roofers performing new sheet metal roofing activities were taking a measurement at the RS4 roof without using fall protection, exposing the roofers to a fall hazard of approximately 46 feet to the ground below.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2926

View EZQUIVEL SHEETMETAL LLC's full OSHA safety record →