On , OSHA opened a complaint safety inspection of JLO METAL PRODUCTS COMPANY, A CORPORATION in 5841 WEST DICKENS AVENUE, CHICAGO, IL 60639 (NAICS 332999). OSHA activity number 345105191.

Watch JLO Metal Products Company, A Corporation — free Get an email when a new federal OSHA severe-injury report for JLO Metal Products Company, A Corporation is published. One employer, no account, unsubscribe in one click.
Site address
5841 WEST DICKENS AVENUE
City
CHICAGO
State
IL
ZIP
60639
Mailing
5841 WEST DICKENS AVENUE, CHICAGO, IL 60639
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
40
Ownership type
A

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5461.00 · Current $3000.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Extruder Department - On April 15, 2021, the employer did not ensure that the Herlan, Impact Extruder machine, number 12-3, had the rotating chuck drive at the top of the extruder machine completely guarded.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5461

1910.219 B01

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $5461.00 · Current $3000.00 Reduced
29 CFR  1910.219(b)(1): Flywheels located so that any part is seven (7) feet or less above floor or platform were not guarded in accordance with the requirements of this subparagraph:  a) Extruder Department - On April 15, 2021, the employer did not ensure that the Herlan, Impact Extruder machines, number 8-6, and 5-5 had the flywheel completely guarded.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5461

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.219(d)(1): Pulleys, with parts of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section:      a) Extruder Department - On April 15, 2021, the employer did not ensure that the Herlan, Impact Extruder machines, number 8-6, had the belt and pulley completely guarded to prevent contact with the moving parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.219(e)(1)(i): Horizontal belts which had both runs seven -7 feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:   a) Extruder Department - On April 15, 2021, the employer did not ensure that the Herlan, Impact Extruder machines, number 8-6, had the belt and pulley completely guarded to prevent contact with the moving parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5461.00 · Current $3000.00 Reduced
29 CFR  1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:  a) Extruder Department East Area of Shop - On April 15, 2021, the employer did not ensure that the electrical light switch panel with exposed buss bars was protected from accidental contact from employees.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5461

1910.22 A02

Other-than-serious 2 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.22(a)(2): The floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition.  When wet processes are used, drainage must be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats must be provided.    a) Extruder Department Central Area - On January 14, 2021, the employer did not ensure that the floor was maintained in a dry condition to prevent slip and fall hazards.  The floor was wet from the roof leak.  b) Extruder Department South Area -  On January 14, 2021, the employer did not ensure that the floor was maintained in a dry condition to prevent slip and fall hazards.  The floor was wet from the roof leak.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0