ERIE, PA —
OSHA Inspection: ERIE FORGE AND STEEL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ERIE FORGE AND STEEL, INC. in 1341 W 16TH STREET, ERIE, PA 16502 (NAICS 332111). OSHA activity number 345110084.
Where did this inspection happen?
- Establishment
- ERIE FORGE AND STEEL, INC.
- Site address
- 1341 W 16TH STREET
- City
- ERIE
- State
- PA
- ZIP
- 16502
- Mailing
- 1341 W 16TH STREET, ERIE, PA 16502
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332111
- Employees
- 70
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.179 N03 I
- Issued
- Abate by
- Penalty
- Initial $6963.00 · Current $4874.00 Reduced
General-duty citation text
29 CFR 1910.179(n)(3)(i): The load was not well secured and properly balanced in the sling or lifting device before it was lifted more than a few inches: a.) Erie Forge & Steel, Inc.; weld area - On or about 1/18/21 and at times prior thereto, a rail was being moved by a 22 ton P & H overhead crane without being secure and balanced. The load shifted and came loose striking an employee in the legs and knocking him down. In addition, devices and/or methods were not utilized to prevent the sling/load from disengaging from the S-Hook rigging configuration. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
- — I (S) $4874.1
- — Z (S) $6963
1910.184 C09
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(c)(9): Employee(s) were not kept clear of load(s) suspended, or about to be lifted by sling(s): a.) Erie Forge & Steel, Inc.; weld area - On or about 1/18/21 and at times prior thereto, a rail was being moved by a 22 ton P & H overhead crane. The load shifted and came loose striking an employee near the load. The employee was struck in the legs and knocked down. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $4642.00 · Current $3249.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a.) Erie Forge & Steel, Inc.; weld area - On or about 1/21/21 and at times prior thereto, a DOALL horizontal bandsaw did not have a guard over the unused portion of the saw blade. The unguarded portion of the saw blade was approximately 10 inches. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement
Recent events (2)
- — I (S) $3249.4
- — Z (S) $4642
More inspections at ERIE FORGE AND STEEL, INC.
ERIE, PA—2021-02-02 00:00:00
ERIE FORGE AND STEEL, INC.
ERIE, PA—2021-02-02 00:00:00
ERIE FORGE AND STEEL, INC.
ERIE, PA—2018-10-05 00:00:00
ERIE FORGE AND STEEL, INC.
ERIE, PA—2018-10-05 00:00:00
ERIE FORGE AND STEEL, INC.
View ERIE FORGE AND STEEL, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332111)
BENSALEM, PA—2026-06-16
SPECIALTY RING PRODUCTS, INC.
NEW BOSTON, MI—2026-05-12
ALCORTA USA INC
AMHERST, NY—2026-05-11
INDUSTRIAL WELDING & FABRICATING CO
WORCESTER, MA—2026-05-06
KOMTEK FORGE LLC
MC KENZIE, TN—2026-04-28
HAVEN STEEL PRODUCTS, INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.