Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JG LUNA CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JG LUNA CONSTRUCTION in 6873 COLONNADE, IRVING, TX 75039 (NAICS 238130). OSHA activity number 345115380.

Watch JG Luna Construction — free Get an email when a new federal OSHA severe-injury report for JG Luna Construction is published. One employer, no account, unsubscribe in one click.
Site address
6873 COLONNADE
City
IRVING
State
TX
ZIP
75039
Mailing
3508 DOUG DR, DALLAS, TX 75247
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $1756.00 Reduced
29 CFR  1926.102(a)(1):The employer, JG Luna Construction did not ensure that each affected employee use appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  On or about January 25, 2021 employees were operating pneumatic nail guns to install framing members without the use of eye protection, exposing them to eye injury hazard.
Recent events (2)
  • — I (S) $1755.6
  • — Z (S) $2926

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2458.00 Reduced
29 CFR  1926.501(b)(13):"Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  On or about January 25, 2021 employees were installing framing members on the upper level of a residential house under construction, approximately 12 feet above ground levels, without fall protection exposing employees to a fall hazard.
Recent events (2)
  • — I (S) $2457.6
  • — Z (S) $4096

1926.1053 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2458.00 Reduced
29 CFR  1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  On or about January 25, 2021 employees were installing framing members on the second level of a residential house under construction utilizing a ladder which did not extend 3 feet above the landing exposing employees to a fall hazard of approximately 12 feet to lower ground level.
Recent events (2)
  • — I (S) $2457.6
  • — Z (S) $4096

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345115380.