Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DWD MECHANICAL CONTRACTOR INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of DWD MECHANICAL CONTRACTOR INC. in 4601 MARKET STREET, PHILADELPHIA, PA 19139 (NAICS 238220). OSHA activity number 345122170.

Watch DWD Mechanical Contractor INC. — free Get an email when a new federal OSHA severe-injury report for DWD Mechanical Contractor INC. is published. One employer, no account, unsubscribe in one click.
Site address
4601 MARKET STREET
City
PHILADELPHIA
State
PA
ZIP
19139
Mailing
1005 KEDRON AVENUE, MORTON, PA 19070
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
4
Ownership type
A

5 citations on file for this inspection.

1910.1200 H01

Other-than-serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $9557.00 · Current $9557.00
29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59)   (a) Jobsite located at 4601 Market St, Philadelphia, PA: Employees were not provided information/training on the hazardous chemicals in their work areas. Employees are exposed to chemicals, including but not limited to:   - Acetylene gas  Condition noted on or about Jan. 27, 2021.
Recent events (2)
  • — I (O) $9557
  • — Z (S) $9557

1926.350 A01

Other-than-serious Gravity 10 3 instances 5 exposed
Issued
Penalty
Initial $9557.00 · Current $9557.00
29 CFR  1926.350(a)(1): The employer did not ensure valve protection caps were in place and secured.   (a) Jobsite located at 4601 Market St., Philadelphia, PA: The employer failed to protect employees against fire and struck-by hazards in that an acetylene gas tank, stored on a ready-to-use welding cart that had not been used for at least 4 days, did not have valve protection caps in place and was connected to a damaged Victor 350 acetylene gas regulator on the first floor, south side near stair tower 3.   (b) Jobsite located at 4601 Market St., Philadelphia, PA: The employer failed to protect employees against fire and struck-by hazards in that an oxygen gas tank, stored on a ready-to-use welding cart that had not been used for at least 4 days, did not have valve protection caps in place on the first floor, south side near stair tower 3.   (c) Jobsite located at 4601 Market St., Philadelphia, PA: The employer failed to protect employees against fire and struck-by hazards in that an acetylene gas tank, stored upright on the floor in front of a gang box for at least 3 days, did not have a valve protection cap in place on the first floor, south side near stair tower 3.   Condition noted on or about Jan. 27, 2021.
Recent events (2)
  • — I (O) $9557
  • — Z (S) $9557

1926.350 A09

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.350(a)(9): Compressed gas cylinders were not secured in an upright position at all times: Note:  This paragraph does not apply to short periods of time while cylinders are being hoisted or carried.   (a)  Jobsite located at 4601 Market St., Philadelphia, PA: Compressed gas cylinders were not secured in an upright position as required in that an acetylene gas tank, stored upright on the floor in front of a gang box for at least 4 days, was not stored in definitely assigned places away from locations where cylinders may be knocked over or damaged by passing or falling objects. The acetylene cylinder was located on the first floor, south side near stair tower 3.   Condition noted on or about Jan. 27, 2021.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.350 F04

Serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.350(f)(4): The employer did not ensure hoses which have been subject to flashback, or which show evidence of severe wear or damage, were tested to twice the normal pressure to which it was subject, but in no case less than 300 p.s.i. :   (a) Jobsite located at 4601 Market St., Philadelphia, PA: The employer failed to protect employees against fire hazards in that a damaged welding torch inlet hose, repaired with 6 inches of duct and putty tape, was connected via regulator to an acetylene gas cylinder on a ready-to-use welding cart on the first floor, south side near stair tower 3.  Condition noted on or about the 3-month period of October 27, 2020 - Jan. 27, 2021.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.350 H

Serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.350(h): Regulators and Gauges.  Oxygen and fuel gas pressure regulators, including their related gauges, were not in proper working order while in use:   (a) Jobsite located at 4601 Market St., Philadelphia, PA: The employer failed to protect employees against fire and struck-by hazards in that a damaged Victor 350 acetylene gas regulator, which was missing its plastic lenses and contained bent pop-out backs on both gauges, was connected to an acetylene gas cylinder on a ready-to-use welding cart on the first floor, south side near stair tower 3.   Condition noted on or about the 3-month period of October 27, 2020 - Jan. 27, 2021.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View DWD MECHANICAL CONTRACTOR INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345122170.