Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WELLBORE INTEGRITY SOLUTIONS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of WELLBORE INTEGRITY SOLUTIONS in RIG #405, 24 MILES NW DIRECTION FROM PECOS, PECOS, TX 79772 (NAICS 211111). OSHA activity number 345127617.

Watch Wellbore Integrity Solutions — free Get an email when a new federal OSHA severe-injury report for Wellbore Integrity Solutions is published. One employer, no account, unsubscribe in one click.
Site address
RIG #405, 24 MILES NW DIRECTION FROM PECOS
City
PECOS
State
TX
ZIP
79772
Mailing
1310 RANKIN ROAD, HOUSTON, TX 77073
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
211111
Employees
33
Ownership type
A

2 citations on file for this inspection.

1910.305 B02

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $843.00 · Current $500.00 Reduced
29 CFR  1910.305(b)(2):Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  Electrical Shock hazard: On or about November 17, 2020, In the truck bed breaker box was observed with missing cover. This condition exposed employees to a electrical shock hazard.
Recent events (2)
  • — I (O) $500
  • — Z (O) $843

1910.334 A02 I

Other-than-serious 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $843.00 · Current $500.00 Reduced
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a)  Electrical shock and fire hazard: On or about November 17, 2021,  The outer jacket to the flexible extension cored was torn. This condition exposed employees to a electrical shock hazard and fire hazard.  b) Electrical Shock and fire hazard: On or about November 17, 2021, Plug to extension cord was damaged. This condition exposed  employees to a electrical shock and fire hazard.
Recent events (2)
  • — I (O) $500
  • — Z (O) $843

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345127617.