Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WINDSOR CONSTRUCTION SERVICES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WINDSOR CONSTRUCTION SERVICES, LLC in 221 SOUTH LUDLOW STREET, DAYTON, OH 45402 (NAICS 236220). OSHA activity number 345145825.

Watch Windsor Construction Services, LLC — free Get an email when a new federal OSHA severe-injury report for Windsor Construction Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
221 SOUTH LUDLOW STREET
City
DAYTON
State
OH
ZIP
45402
Mailing
6660 DOUBLETREE AVE SUITE #8, COLUMBUS, OH 43229
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
30
Ownership type
A

4 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 3 instances 4 exposed
Issued
Penalty
Initial $10513.00 · Current $5257.00 Reduced
29 CFR  1926.20(b)(2):The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s)  There was no frequent and regular inspection program being maintained in use by a competent person to ensure the jobsite, materials and equipment such as protection of energized construction temporary string lights lamp/bulbs from physical accidental contact or breakage damage, energized 400 volt breaker panel interior uninsulated energized lugs and wiring being protected by guarding arranged and of such strength as to prevent physical damage and adequately protected elevator doorway wall openings were being maintained and utilized in a safe condition.
Recent events (2)
  • — I (S) $5256.5
  • — Z (S) $10513

1926.403 I02 II

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $10513.00 · Current $5257.00 Reduced
29 CFR  1926.403(i)(2)(ii):In locations where electric equipment operating at 600 volts, nominal, or less is exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage:  Located in the central area of the basement adjacent to the elevator shaft there was an observed energized 400 volt breaker panel cabinet without the face or trim cover to effectively close the breaker panel exposing employees to the lack of adequately guarding live parts, in that the face panel opening and interior uninsulated energized lugs and wiring were covered or partially with cardboard which was not so arranged and of such strength as to prevent physical damage.
Recent events (2)
  • — I (S) $5256.5
  • — Z (S) $10513

1926.405 A02 II E

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $10513.00 · Current $0.00 Reduced
29 CFR  1926.405(a)(2)(ii)(E):Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:  Located on the first, second, third, fourth floor work areas and hallways there were employees observed exposed to sets of energized temporary construction string lights on which the light lamp/bulbs were not protected from physical accidental contact or breakage damage by plastic cage bulb guards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10513

1926.501 B13

Serious Gravity 10 4 instances 3 exposed
Issued
Penalty
Initial $10513.00 · Current $5257.00 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system.  Located along various floor / stairwell areas from the basement to the fifth floors of the residential structure employees were observed working and accessing adjacent to inadequately protected elevator doorway wall openings in that there was unsecured plywood or sheet metal laying unsecured in front of the elevator doorway wall openings exposing employees to fall potentials up to in excess of 40 feet.
Recent events (2)
  • — I (S) $5256.5
  • — Z (S) $10513

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345145825.