Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DESIGN & CONSTRUCTION INNOVATIONS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DESIGN & CONSTRUCTION INNOVATIONS, LLC in 15123 OGDEN LOOP, ODESSA, FL 33556 (NAICS 236220). OSHA activity number 345149983.

Watch Design & Construction Innovations, LLC — free Get an email when a new federal OSHA severe-injury report for Design & Construction Innovations, LLC is published. One employer, no account, unsubscribe in one click.
Site address
15123 OGDEN LOOP
City
ODESSA
State
FL
ZIP
33556
Mailing
20625 AMBERFIELD DRIVE, LAND O LAKES, FL 34638
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
19
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $5461.00 · Current $2731.00 Reduced
29 CFR  1926.501(b)(11):Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  a) On or about February 16, 2021, at the Odessa Jobsite, employees performing roof work were exposed to a 10 foot 9 inch fall hazard, in that, fall protection was not used on the 5:12 pitched roof.
Recent events (2)
  • — I (S) $2730.5
  • — Z (S) $5461

1926.1053 B01

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $5461.00 · Current $2731.00 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On or about February 16, 2021, at the Odessa Jobsite, employees performing roof work were exposed to a 10 foot 9 inch fall hazard, in that, the ladder side rails of the Werner ladder did not extend 3 feet above the upper landing surface.