Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CENTENNIAL AIRCRAFT INTERIORS INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of CENTENNIAL AIRCRAFT INTERIORS INC. in 7405 SOUTH PEORIA STREET, ENGLEWOOD, CO 80112 (NAICS 488190). OSHA activity number 345158224.

Watch Centennial Aircraft Interiors INC. — free Get an email when a new federal OSHA severe-injury report for Centennial Aircraft Interiors INC. is published. One employer, no account, unsubscribe in one click.
Site address
7405 SOUTH PEORIA STREET
City
ENGLEWOOD
State
CO
ZIP
80112
Mailing
7405 SOUTH PEORIA STREET, ENGLEWOOD, CO 80112
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488190
Employees
6
Ownership type
A

6 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 2 instances 2 exposed
Issued
Penalty
Initial $1755.00 · Current $1000.00 Reduced
29 CFR  1910.134(c)(1):A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  (a) 7405 South Peoria Street, Englewood CO 80112:  On or about February 23, 2021, and at times prior, the employer did not establish and implement a written respiratory program which included provisions including but not limited to: medically clearing employees prior wear of the respirator; fit-testing employees upon initial assignment and annually thereafter; and storage of respirators in a manner which prevents contamination.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1755

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(e)(1):The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) 7405 South Peoria Street, Englewood CO 80112:  On or about February 23, 2021, and at times prior, employees were not evaluated by a medical professional prior to use of the respirator.  Employees who are not medically cleared prior to use of a respirator may be exposed to situations that aggravate existing pre-existing medical conditions, such as asthma or claustrophobia.  Employees may have pre-existing medical conditions which compromise the wear of the respirator, such as punctured ear drums.  Employees wear a half-face elastomeric respirator while performing touch-up spray painting.    Note:  The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(f)(2):Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  (a) 7405 South Peoria Street, Englewood CO 80112:  On or about February 23, 2021, and at times prior, employees were not fit-tested prior to initial use of a 3M 6200 half-face elastomeric respirator.  Employees perform touch-up spray painting on parts while wearing the respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(h)(2)(i):Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:  (a) 7405 South Peoria Street, Englewood CO 80112:  On or about February 23, 2021, and at times prior, respirators were not stored in a manner to protect them from contamination.  Employees are using respirators to perform touch-up painting of parts.  Respirators are stored in the painting room and are not protected from overspray of paint, exposing employees to skin irritation or other dermal hazards.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K06

Serious Gravity 1 4 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  (a) 7405 South Peoria Street, Englewood CO 80112: On or about February 23, 2021, and at times prior, the employer did not provide the information contained in 1910.134, Appendix D to employees who voluntarily used NIOSH-approved filtering face-piece devices such as an N95.  Abatement Note:  Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F06 II

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1755.00 · Current $1000.00 Reduced
29 CFR  1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  (a)  7405 South Peoria Street, Englewood CO 80112:  On or about February 23, 2021, and at times prior, employees used a spray bottle containing Jet-A fuel which was not labeled in accordance with requirements stated in 1910.1200.  Jet-A fuel is a skin irritant and inhalation of fuel vapors may cause nausea, headache, dizziness and intoxication.  Employees use the fuel periodically to remove adhesive.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1755

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345158224.