CORPUS CHRISTI, TX —
OSHA Inspection: ALVAREZ TUNNELING & ROOFING INC
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of ALVAREZ TUNNELING & ROOFING INC in 8761 STATE HIGHWAY 44, CORPUS CHRISTI, TX 78406 (NAICS 237990). OSHA activity number 345163257.
Where did this inspection happen?
- Establishment
- ALVAREZ TUNNELING & ROOFING INC
- Site address
- 8761 STATE HIGHWAY 44
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78406
- Mailing
- 2822 BALDWIN, CORPUS CHRISTI, TX 78405
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237990
- Employees
- 15
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.651 B01
- Issued
- Penalty
- Initial $5461.00 · Current $5461.00
General-duty citation text
29 CFR 1926.651(b)(1): The estimated location of utility installations, such as sewer, telephone, fuel, electric, water lines, or any other underground installations that reasonably may be expected to be encountered during excavation work, was not determined prior to opening an excavation. On or about February 23,2021 at this work place, employees conducted excavation operations to repair water leaks under a building foundation, and the location of utilities such as but not limited to: electrical and water lines were not determined prior to the opening of the excavation.
Recent events (1)
- — Z (S) $5461
1926.651 G01 II
- Issued
- Penalty
- Initial $5461.00 · Current $5461.00
General-duty citation text
29 CFR 1926.651(g)(1)(ii): Adequate precautions were not taken to prevent employee exposure to atmospheres containing less than 19.5 percent oxygen and other hazardous atmospheres. On or about February 23,2021 at this work place, employees conducted excavation operations to repair water leaks under a building foundation, and adequate precautions were not taken to prevent employee exposure to atmospheres containing less than 19.5 percent oxygen and other hazardous atmospheres.
Recent events (1)
- — Z (S) $5461
1926.651 G02 I
- Issued
- Penalty
- Initial $5461.00 · Current $5461.00
General-duty citation text
29 CFR 1926.651(g)(2)(i): Emergency rescue equipment, such as breathing apparatus, a safety harness and line, or a basket stretcher, was not readily available where hazardous atmospheric conditions existed or could reasonably be expected to develop during. On or about February 23,2021 at this work place, employees conducted excavation operations to repair water leaks under a building foundation, and emergency rescue equipment was not available.
Recent events (1)
- — Z (S) $5461
1926.651 H01
- Issued
- Penalty
- Initial $5461.00 · Current $5461.00
General-duty citation text
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation. On or about February 23,2021 at this work place, employees conducted excavation operations to repair water leaks under a building foundation, and adequate means were not taken to protect employees against the hazards posed by water accumulation.
Recent events (1)
- — Z (S) $5461
1926.651 I02 IV
- Issued
- Penalty
- Initial $5461.00 · Current $5461.00
General-duty citation text
29 CFR 1926.651(i)(2)(iv): A registered professional engineer did not approve the determination that such excavation work will not pose a hazard to employees. On or about February 23,2021 at this work place, employees conducted excavation operations to repair water leaks under a building foundation, and a registered professional engineer did not determine that such excavation would not pose a hazard to employees.
Recent events (1)
- — Z (S) $5461
1926.652 A01
- Issued
- Penalty
- Initial $3901.00 · Current $3901.00
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). On or about February 23,2021 at this work place, employees conducted excavation operations to repair water leaks under a building foundation, and were not protected from a cave-in by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).
Recent events (1)
- — Z (S) $3901
More inspections at ALVAREZ TUNNELING & ROOFING INC
CORPUS CHRISTI, TX—2023-07-06 00:00:00
ALVAREZ TUNNELING & ROOFING INC
CORPUS CHRISTI, TX—2022-04-13 00:00:00
ALVAREZ TUNNELING & ROOFING INC
CORPUS CHRISTI, TX—2022-01-31 00:00:00
ALVAREZ TUNNELING & ROOFING INC
View ALVAREZ TUNNELING & ROOFING INC's full OSHA safety record →
More inspections in this industry (NAICS 237990)
HARTFORD CITY, IN—2026-07-10
WHITE CONSTRUCTION
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SAN LEANDRO, CA—2026-07-07
SHIMMICK CONSTRUCTION COMPANY, INC
FIRCREST, WA—2026-07-07
WA317991974 - CONTINENTAL DIRT CONTRACTORS
STEVENSVILLE, MD—2026-07-07
KOKOSING INDUSTRIAL, INC.
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345163257.