SHAWNEE, OK —
OSHA Inspection: JOSE A. VEGA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JOSE A. VEGA in 1611 LADY LN / VIRGIE INTERSECTION NW CORNER HOME, SHAWNEE, OK 74801 (NAICS 238160). OSHA activity number 345166490.
Where did this inspection happen?
- Establishment
- JOSE A. VEGA
- Site address
- 1611 LADY LN / VIRGIE INTERSECTION NW CORNER HOME
- City
- SHAWNEE
- State
- OK
- ZIP
- 74801
- Mailing
- 2411 SE 11TH ST., OKLAHOMA CITY, OK 73129
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $2487.00 · Current $1492.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b). On or about February 23, 2021, the employer did not ensure that employees were in use of fall protection when performing roofing work activities from the roof of a residential building. This exposed the employees to a fall hazard greater than six (6) feet to the ground below.
Recent events (2)
- — I (S) $1492.2
- — Z (S) $2487
1926.1053 B01
- Issued
- Penalty
- Initial $2341.00 · Current $1405.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. On or about February 23, 2021, the employer did not ensure that the side rails of the extension ladder extended at least three(3) feet above the roof landing. The employees used the extension ladder to gain access to the roof and this exposed the employees to a fall hazard.
Recent events (2)
- — I (S) $1404.6
- — Z (S) $2341
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in OK
TULSA, OK—2026-07-15
LA UNION 7 LLC
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION