Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WALTHER CALDERON

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of WALTHER CALDERON in 9250 BOYD COOPER PARKWAY, MONTGOMERY, AL 36117 (NAICS 238160). OSHA activity number 345202055.

Watch Walther Calderon — free Get an email when a new federal OSHA severe-injury report for Walther Calderon is published. One employer, no account, unsubscribe in one click.
Establishment
WALTHER CALDERON
Site address
9250 BOYD COOPER PARKWAY
City
MONTGOMERY
State
AL
ZIP
36117
Mailing
2686 MCCLAVE DR., DORAVILLE, GA 30340
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
9
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $4096.00
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) On or about March 9, 2021 at 9250 Boyd Cooper Parkway, Montgomery, Al. 36117; The employer exposed employees to fall hazards of 45 feet from eave to ground while conducting removal and installation of roof shingles due to employees not having their personal fall arrest system connected with a rope, lanyard, and anchor.
Recent events (1)
  • — Z (S) $4096

1926.1053 B01

Serious Gravity 1 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $1755.00 · Current $1755.00
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) On or about March 9, 2021 at 9250 Boyd Cooper Parkway, Montgomery, Al. 36117; The employer exposed employees to fall hazards when employees used two different extension ladders to gain access onto/off the roof due to the ladders not extending 3 feet above the landing surface.
Recent events (1)
  • — Z (S) $1755

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345202055.