Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FOOD AND DRUG ADMINISTRATION PACIFIC NORTHWEST LABORATORY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FOOD AND DRUG ADMINISTRATION PACIFIC NORTHWEST LABORATORY in 22201 23RD DRIVE SE, BOTHELL, WA 98021 (NAICS 926140). OSHA activity number 345202766.

Watch Food AND Drug Administration Pacific Northwest Laboratory — free Get an email when a new federal OSHA severe-injury report for Food AND Drug Administration Pacific Northwest Laboratory is published. One employer, no account, unsubscribe in one click.
Site address
22201 23RD DRIVE SE
City
BOTHELL
State
WA
ZIP
98021
Mailing
22201 23RD DRIVE SE, BOTHELL, WA 98021
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
926140
Employees
65
Ownership type
D

2 citations on file for this inspection.

1910.1200 F06 II

Repeat 2 instances 6 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(f)(6)(ii):Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.  a)	Microbiology Laboratory Room 133;  There was a secondary bottle of isopropanol which was not labeled with the percentage of alcohol and hazard label warnings.   b)	Microbiology Laboratory, Room 193;  There was a secondary container of 75% Ethanol with no hazard label warnings.   The Food and Drug Administration was previously cited for a violation of this occupational safety and health standard or its equivalent, which was contained in OSHA inspection number 1359210, citation number 2, item number 2and was affirmed as a final order on 05/30/2019, with respect to a workplace located at Seattle, WA.  The Food and Drug Administration was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1354074, citation number 1, item number 1 and was affirmed as a final order on 11/20/2018, with respect to a workplace located at Tacoma, WA.
Recent events (1)
  • — Z (R) $0

1910.157 C01

Other-than-serious 14 instances 50 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(c)(1):The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.  (a)	 Microbiology Laboratory Room 95;  There was not an identifying sign over the Amerex fire extinguisher.  (b)	Microbiology Laboratory Room 93;  There was not an identifying sign over the Badger fire extinguisher.  (c)	Media Prep Space, Room 139;  There was not an identifying sign over the Amerex fire extinguisher.  (d)	Extraction Laboratory,  Room 146;  There was not an identifying sign of the Amerex fire extinguisher.  (e)	Room 148;  There was not an identifying sign over the Amerex fire extinguisher.  (f)	Room 149;  There was not an identifying sign over the Amerex fire extinguisher.  (g)	Room 150;  There was not an identifying sign over the Cintas fire extinguisher.  (h)	Room 151;  There was not an identifying sign over the Amerex fire extinguisher.  (i)	Room 128;  There was not an identifying sign over the Advantage fire extinguisher.  (j)	Room 129;  There was not an identifying sign over the Advantage fire extinguisher.  (k)	Room 130;  There was not an identifying sign over the Cintas fire extinguisher.  (l)	Room 131;  There was not an identifying sign over the Badger fire extinguisher.  (m)	Chemistry Laboratory Hallway;  Room 223, there was not an identifying sign over the Buckeye fire extinguisher.  (n)	Room 224;  There was not an identifying sign over the Badger fire extinguisher.