Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KAMAN AIR VEHICLES

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of KAMAN AIR VEHICLES in 1332 BLUE HILLS AVENUE, BLOOMFIELD, CT 06002 (NAICS 336411). OSHA activity number 345208680.

Watch Kaman AIR Vehicles — free Get an email when a new federal OSHA severe-injury report for Kaman AIR Vehicles is published. One employer, no account, unsubscribe in one click.
Establishment
KAMAN AIR VEHICLES
Site address
1332 BLUE HILLS AVENUE
City
BLOOMFIELD
State
CT
ZIP
06002
Mailing
30 OLD WINDSOR ROAD, BLOOMFIELD, CT 06002
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336411
Employees
150
Ownership type
A

12 citations on file for this inspection.

1910.124 H04

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $13653.00 · Current $9557.00 Reduced
29 CFR  1910.124(h)(4): Employees working with chromic acid were not provided with periodic examinations of their exposed body parts, especially their nostrils:  Building 11:  On or about April 28, 2021, employees responsible for electroplating operations in dip tanks containing 50-60% chromium (VI) oxide did not have body parts, especially their nostrils, examined. A dip tank located in the CAD Plating Room of building 11 was used every day by employees responsible for electroplating tasks.
Recent events (2)
  • — I (S) $9557
  • — Z (S) $13653

1910.1026 K01 I A

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $13653.00 · Current $0.00 Reduced
29 CFR  1910.1026(k)(1)(i)(A): The employer did not make medical surveillance available for all employees who were or could be occupationally exposed to chromium (VI) at or above the action level for 30 or more days a year:  Building 2:  On or about May 3, 2021, employees engaged in operations that require frequent exposures to hexavalent chromium in building 2 were not provided with medical surveillance to determine potential adverse health effects. An exposure assessment performed on May 03, 2021, showed that employees working in the Paint Shop Room, Etch Line Room, and Sanding Room in Building 2 were exposed to an 8-hr concentration of 16�g/m3, which exceeded OSHA's 5�g/m3 PEL, requiring the need for medical surveillance.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13653

1910.1026 C

Serious Gravity 10 3 instances 3 exposed
Issued
Penalty
Initial $13653.00 · Current $9557.00 Reduced
29 CFR  1910.1026(c): The employer did not ensure that no employee was exposed to an airborne concentration of chromium (VI) in excess of 5 micrograms per cubic meter of air (ug/m3), calculated as an 8-hour time-weighted average (TWA).  Building 2 Paint Shop:  On or about, and at times after May 03, 2021, employees that were assigned to Building 2 Paint Shop were exposed to hexavalent chromium (Cr6+) in exceedance of OSHA's permissible exposure limit (PEL) with an 8-hour time-weighted average (TWA) concentration of 16�g/m3. Employees were exposed to Cr6+ while performing preparation, mixing, and painting with a 515X410 Base Component containing >20 - <22% strontium chromate and 3M Scotch-Weld Structural Adhesive Primer EC-3917 containing 1-5% strontium chromate. Additional exposures were noted during electroplating operations with one dip tank containing an Alodine solution of 50-60% chromium (VI) oxide and another containing sulfuric acid sodium dichromate at 100%.
Recent events (2)
  • — I (S) $9557
  • — Z (S) $13653

1910.1026 F01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1026(f)(1)(i):Feasible engineering controls and work practices were not instituted to reduce and maintain employee exposures to chromium (VI) at or below the permissible exposure limit:  Building 2  On or about May 3, 2021, engineering and work practice controls were not fully implemented resulting in hexavalent chromium overexposures at 16�g/m3 over an 8-hour time-weighted average. Controls and work practices were not consistently implemented in the spray painting and electroplating rooms located in building 2 where the 8-hour 5�g/m3 permissible exposure limit (PEL) was exceeded.
Recent events (4)
  • — P (S) $0
  • — P (S) $0
  • — I (S) $0

1910.134 G

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 0689

29 CFR  1910.134(g): The employer did not establish and implement procedures for the proper use of respirators, including taking action to ensure continued effective respirator operation throughout the work shift:    Building 2:  On or about May 03, 2021, employees were exposed to hexavalent chromium above the permissible exposure level and the employer did not ensure that effective respiratory protection was used.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 L01 III

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $13653.00 · Current $9557.00 Reduced
29 CFR  1910.1026(l)(1)(iii): The employer did not include chromium (VI) in the hazard communication program established to comply with the HCS (� 1910.1200);  did not ensure that each employee has access to labels on containers of chromium (VI) and to safety data sheets; and that each employee was trained in accordance with the requirements of HCS and paragraph (l)(2) of this section:   a) Building 11:  On or about April 28, 2021, employees performing electroplating with a dip tank of hexavalent chromium (Cr6+) compounds, located in the CAD Plating Shop of building 11, were not provided with general information regarding the physical and health hazards of the chemical in the tank.  Additional Cr6+ exposures during the cadmium plating process had not been reviewed with employees.  Employees were unaware of the hazards of the chemicals they were handling while performing their duties, and had not been provided adequate training on these exposures or the requirements and purpose of the Hexavalent Chromium Standard.   b) Building 2: On or about May 03, 2021 employees working in the Etch Line Room, Paint Shop Room, and Sanding Room were unaware that the products they used during mixing, prep, and painting operations were Cr6+ containing. The employer did not ensure that employees were aware of the required control measures and the adverse effects associated with exposures to this carcinogen.
Recent events (2)
  • — I (S) $9557
  • — Z (S) $13653

1910.1200 F06 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.  Building 2 Etch Line Room:  On or about April 28, 2021, the employer did not ensure that dip tanks in the Etch Line room of Building 2 were labeled with information about the identity and the hazards of the tank contents. Employees frequently work in the room performing electroplating tasks. Tanks stored in the room included 11 Dip tanks labeled: phosphoric acid, spray DI water, four immersion DI rinse water tanks, DI water, spray rinse, sulfuric acid sodium dichromate, alkaline cleaner, spray rinse, and Alodine 1200s.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 D01

Willful Gravity 10 2 instances 3 exposed
Issued
Penalty
Initial $136532.00 · Current $95572.00 Reduced
29 CFR  1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):  a) Building 2:  On or about May 3, 2021, the employer did not make a determination of employee exposure to hexavalent chromium (Cr(VI)) during electroplating, mixing and preparation, painting, and paint removal operations on small aircraft parts. Employees in the Building 2 Paint Shop performed tasks that included Cr(VI) mixing, preparation, and sanding with a Duracoat putty containing 10-20% Cr(VI) trioxide that was mixed with an Evercoat Polyester Glazing Putty. Also, a 515X410 Base Component containing 20% strontium chromate and an M&D Activator Component was mixed then spray painted onto small parts. Additional spray painting in building 2 was done with a 3M Structural Adhesive Primer EC-3917 that contained a 1-5% strontium chromate concentration. Employees also worked in an Etch Line room (connected to the Paint Shop room), which included a process line of one dip tank containing 100% strontium chromate and another dip tank containing 50-60% Cr(VI) oxide Alodine solution. An exposure assessment performed by OSHA during the inspection resulted in an exceedance of the 5ug/m3 PEL in building 2 with an 8hr TWA concentration of 16�g/m3.   b) Building 11:  On or about April 28, 2021, plating operations performed in building 11 also included the use of a Duracoat product containing 10-20% chromic acid while cadmium plating and performing electroplating operations in a small dip tank containing a 50-60% Cr(VI) oxide Alodine solution. Cr(VI) samples retrieved from building 11 resulted in exposure levels below the PEL with an 8hr TWA concentration of 0.07 �g/m3.
Recent events (2)
  • — I (W) $95572
  • — Z (W) $136532

1910.1026 H01

Willful Gravity 10 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1026(h)(1): A hazard was present or was likely to be present from skin or eye contact with chromium (VI); however, the employer did not provide appropriate personal protective clothing and equipment at no cost to employees, and/or did not ensure that employees used such clothing and equipment:   a) Building 2:  On or about May 03, 2021, the employer did not ensure that affected employees in the Paint Shop Room and Etch Line Room were provided and using the appropriate personal protective equipment such as, but not limited to, chemical-resistant gloves and impervious aprons while performing electroplating, painting, and paint removal tasks to protect from chromium (VI) hazards.  b) Building 11:  On or about April 28, 2021, the employer did not ensure that affected employees in the CAD Plating Shop were provided and using the appropriate personal protective equipment such as, but not limited to, chemical-resistant gloves and impervious aprons while performing plating operations to protect from chromium (VI) hazards.
Recent events (2)
  • — I (W) $0
  • — Z (W) $0

1910.1027 D01 II

Willful Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $117024.00 · Current $81917.00 Reduced
29 CFR  1910.1027(d)(1)(ii): Determination of employee exposure was not made from breathing zone air samples that reflect the monitored employee's regular, daily 8-hour TWA exposure to cadmium:  Building 11 CAD Plating Shop:  On or about April 28, 2021, employees responsible for performing cadmium plating operations were not assessed to determine if they were overexposed to the toxic substance. Cadmium plating is performed between four to five times in a month over an eight hour work day.
Recent events (2)
  • — I (W) $81917
  • — Z (W) $117024

1910.134 C01

Other-than-serious 1 instance 75 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(c)(1):  A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  Company-wide:  On or about March 22, 2021, the employer did not disclose worksite specific procedures for the various workstations that require the use of a respirator in their written respiratory protection program.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 75 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(e)(1)(i):  The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  Company-wide:  On or about March 22, 2021, the employer did not compile a list of chemicals used on-site that identified the hazards in areas such as the Cadmium Plating, Avionics, and X-Ray Shop in building 11 or the Paint Shop and Etch Line Room in building 2. Some of the known hazards present included, but were not limited to, an Alodine 1200S solution of 50-60% chromium (VI) oxide, a solution of sulfuric acid sodium dichromate at 100%, a Duracoat putty containing 10-20% Cr(VI) trioxide, 515X410 Base Component containing 20% strontium chromate, 3M Structural Adhesive Primer EC-3917 that contained a 1-5% strontium chromate concentration, 99.5-100% Methyl ethyl ketone wipes, and Cadmium No-Bake containing 15-20% cadmium sulphate.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345208680.