Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CARLITOS CONSTRUCTION SVCS., INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CARLITOS CONSTRUCTION SVCS., INC in 27 BEDFORD RD., WOBURN, MA 01801 (NAICS 238160). OSHA activity number 345212435.

Watch Carlitos Construction Svcs., INC — free Get an email when a new federal OSHA severe-injury report for Carlitos Construction Svcs., INC is published. One employer, no account, unsubscribe in one click.
Site address
27 BEDFORD RD.
City
WOBURN
State
MA
ZIP
01801
Mailing
176 MAMMOTH RD., APT. 1, LOWELL, MA 01854
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were an employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   Jobsite:  On or about February 26, 2021, employees engaged in roofing work were not protected from falls of 10-feet to 23-feet to grade.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1926.1053 B01

Serious Gravity 10 3 instances 3 exposed
Issued
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR  1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  Jobsite:  On or about February 26, 2021, the four aluminum extension ladders, used by employees to access the roof of the home, did not extend three feet beyond the roof surface.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1926.1053 B07

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1053(b)(7): Ladder(s) that were unsecured or not provided with slip-resistant feet were used on slippery surfaces:    Jobsite:  On or about February 26, 2021, the slip-resistant feet of the 32-ft aluminum extension ladder, used by employees to access the roof of the home, were not in contact with the asphalt driveway.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345212435.