Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PETRO PLUS CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PETRO PLUS CONSTRUCTION, INC. in 40028 HWY 42, GALVEZ, LA 70769 (NAICS 238910). OSHA activity number 345234645.

Watch Petro Plus Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Petro Plus Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
40028 HWY 42
City
GALVEZ
State
LA
ZIP
70769
Mailing
26904 JAMES CHAPEL ROAD NORTH, HOLDEN, LA 70744
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
3
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2926.00 · Current $585.00 Reduced
Occupational Safety and Health Act of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards causing or likely to cause death or serious physical harm to employees in that employees are exposed to a fall hazards.   On or about April 6, 2021, on the southwest side of the site; an employee was lifted while standing inside an excavation bucket that was being lowered into the excavation trench.
Recent events (3)
  • — F (S) $585.2
  • — C (S) $2926
  • — Z (S) $2926

1926.501 B01

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4096.00 · Current $819.00 Reduced
29 CFR  1926.501(b)(1):):"Unprotected sides and edges."  Employees on walking/working surfaces with an unprotected side and/or edge which is 6 feet or more above a lower level were not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:   On or about April 6, 2021, on southwest side of site, an employee  was observed standing on top and subsequently riding a fuel storage tank approximately seven (7) feet in height while being hoisted by the excavator from ground to bottom of the excavation without adequate fall protection.
Recent events (3)
  • — F (O) $819.2
  • — C (S) $4096
  • — Z (S) $4096

1926.501 B07 II

Other-than-serious Gravity 10 1 instance 3 exposed
Issued
Penalty
Initial $4096.00 · Current $819.00 Reduced
29 CFR  1926.501(b)(7)(ii):Each employee at the edge of a well, pit, shaft, or  similar excavation 6 feet (1.8 m) or more in depth was not protected from falling by guardrail systems, fences, barricades, or covers.  On or about April 6, 2021, southwest side of site employees worked around the edge of an open excavation that was over six (6) feet in depth with no barriers, guardrails, or personal fall protection. The excavation was approximately seventeen feet in depth and seventeen feet in width.
Recent events (3)
  • — F (O) $819.2
  • — C (S) $4096
  • — Z (S) $4096

1926.651 C02

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4096.00 · Current $819.00 Reduced
29 CFR  1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations 4 feet or more in depth to require no more than 25 feet of lateral travel for employees.   On or about April 6, 2021, Southwest side of the job site, employees entered an excavation approximately seventeen (17) feet in deep in order to install an underground fuel storage tank, without a means of safe egress.
Recent events (3)
  • — F (O) $819.2
  • — C (S) $4096
  • — Z (S) $4096

1926.651 E

Other-than-serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $4096.00 · Current $819.00 Reduced
29 CFR  1926.651(e): Employee was not prohibited to be underneath loads handled by lifting or digging equipment.   On or about April 6, 2021, southwest side of the job site, employees installed an underground fuel tank in an excavation and underneath an excavator bucket while the excavator was backfilling the excavation approximately seventeen (17) feet in depth.
Recent events (3)
  • — F (O) $819.2
  • — C (S) $4096
  • — Z (S) $4096

1926.652 A01

Other-than-serious Gravity 10 2 instances 2 exposed
Issued
Penalty
Initial $4096.00 · Current $819.00 Reduced
29 CFR  1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).   On or about April 6, 2021, on the southwest side of the site employees installed an underground fuel storage tank while in an excavation at a depth of approximately seventeen (17) feet deep and seventeen (17) feet wide without an adequate protective system..
Recent events (3)
  • — F (O) $819.2
  • — C (S) $4096
  • — Z (S) $4096

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345234645.