HUDSON, WI —
OSHA Inspection: PRECO, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PRECO, INC. in 2251 WILLIS MILLER DRIVE, HUDSON, WI 54016 (NAICS 339112). OSHA activity number 345239446.
Where did this inspection happen?
- Establishment
- PRECO, INC.
- Site address
- 2251 WILLIS MILLER DRIVE
- City
- HUDSON
- State
- WI
- ZIP
- 54016
- Mailing
- 2251 WILLIS MILLER DRIVE, HUDSON, WI 54016
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339112
- Employees
- 54
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $136532.00 · Current $95572.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On the west side of the production area; On or about March 24, 2021, one or more methods of machine guarding was not provided to protect employees from ingoing nip points on a Preco brand, Model RCP 7-14, 10-inch Rotary Converting Platform, Serial No. RCPA-0016. (b) On the east side of the production area; On or about March 23, 2021, one or more methods of machine guarding was not provided to protect employees from ingoing nip points on a Preco brand, Model RCP 5-10, 13-inch Rotary Converting Platform with laser, Serial No. 6375.
Recent events (2)
- — I (W) $95572.4
- — Z (W) $136532
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Throughout the production area; On or about March 24, 2021, the employer did not conduct periodic inspections of the machine specific energy control procedures on an at least annual basis.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PRECO, INC.
BOISE, ID—2018-02-08 00:00:00
PRECO, INC.
3075SA SPRINGS, CO—2004-08-04 00:00:00
PRECO INC.
AMHERST, MA—1991-05-23 00:00:00
PRECO, INC.
HOOKSETT, NH—1990-09-05 00:00:00
PRECO, INC.
Boise, ID—1983-06-23 00:00:00
PRECO INC
View PRECO, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339112)
PEACHTREE CITY, GA—2026-06-11
GERRESHEIMER PEACHTREE CITY (USA), L.P.
MARSHFIELD, MA—2026-06-11
KIRWAN SURGICAL PRODUCTS LLC
HOUSTON, TX—2026-06-11
ALCON LABORATORIES, INC.
OSSEO, MN—2026-05-27
111319 - BOSTON SCIENTIFIC CORPORATION
DRAPER, UT—2026-05-21
EDWARDS LIFESCIENCES, LLC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345239446.