SYRACUSE, NY —
OSHA Inspection: ESSILOR OF AMERICA
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ESSILOR OF AMERICA in 2840 ERIE BLVD EAST, SYRACUSE, NY 13224 (NAICS 339115). OSHA activity number 345250914.
Where did this inspection happen?
- Establishment
- ESSILOR OF AMERICA
- Site address
- 2840 ERIE BLVD EAST
- City
- SYRACUSE
- State
- NY
- ZIP
- 13224
- Mailing
- 2840 ERIE BLVD EAST, SYRACUSE, NY 13224
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339115
- Employees
- 98
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.242 B
- Issued
- Penalty
- Initial $4973.00 · Current $3232.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) ES5 Area; on or about 4/14/2021: Compressed air used for cleaning purposes measured at 116.5 p.s.i. b) Digital Surfacing Area, on or about 4/14/21: Compressed air used for cleaning purposes measured at 84.7 p.s.i.
Recent events (2)
- — I (S) $3232
- — Z (S) $4973
1910.303 G02 I
- Issued
- Penalty
- Initial $6632.00 · Current $4310.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): a) Wash Up Frame Station Area, on or about 4/14/21: A 120/240 volt breaker panel box labeled Lab #3 had two blanks missing. b) Surfacing Area, on or about 4/14/21: A 120/240 volt breaker panel box labeled Lab #1 had one blank missing. c) Time Clock Area, on or about 4/14/21: A 120/208 volt breaker panel box had an opening measuring 1/2" x 2.5".
Recent events (2)
- — I (S) $4310
- — Z (S) $6632
1910.1027 D01 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1027(d)(1)(i):The employer did not determine whether any employee was exposed to cadmium at or above the action level: a) Recycling Area, on or about 4/21/21: Employee adhering lenses to alloy blocks containing cadmium on B4 Blocking Machine. Employer had not conducted initial monitoring to determine employee exposure.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 339115)
LARGO, FL—2026-06-17
AMERICAN POLYLITE
JUANA DIAZ, PR—2025-09-11
SAMPOL PUERTO RICO LLC
WARWICK, RI—2025-06-12
ESSILOR OPERATING LLC
LOUISVILLE, KY—2025-06-12
68062 - ESSILOR LABORATORIES OF AMERICA INC
SALT LAKE CITY, UT—2025-05-29
LUMENIS INC.
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345250914.