Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION DRILLING CORPORATION, LP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRECISION DRILLING CORPORATION, LP in IGUANA UNIT 6A15, WELL 15H, PECOS, TX 79772 (NAICS 213111). OSHA activity number 345252100.

Watch Precision Drilling Corporation, LP — free Get an email when a new federal OSHA severe-injury report for Precision Drilling Corporation, LP is published. One employer, no account, unsubscribe in one click.
Site address
IGUANA UNIT 6A15, WELL 15H
City
PECOS
State
TX
ZIP
79772
Mailing
10350 RICHMOND AVE SUITE #700, HOUSTON, TX 77042
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
500
Ownership type
A

4 citations on file for this inspection.

1910.134 F02

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7802.00 · Current $5000.00 Reduced
29 CFR  1910.134(f)(2):Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:  Drilling Site: On or about April 8, 2021, the  employer did not ensure employees engaged in drilling operations in a Hydrogen Sulfide field and were prepared to conduct a rescue had completed fit testing on the rescue respirators.  This condition exposed employees to health hazards.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $7802

1910.304 G05

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7802.00 · Current $5000.00 Reduced
29 CFR  1910.304(g)(5):The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  Drilling Site: On or about April 08, 2021, the employer did not ensure the Lube Roll-Off trailer and crew quarters were grounded which are located on a Hydrogen Sulfide field and are powered by portable power.  This condition exposed employees to fire and electrical shock hazards.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $7802

1910.1200 H03 III

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7802.00 · Current $5000.00 Reduced
29 CFR  1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used:  Drilling Site: On or about April 8, 2021, the employer did not ensure employees engaged in drilling activities on a Hydrogen Sulfide field were trained to conduct a rescue with a Self Contained Breathing Apparatus (SCBA).  This condition exposed employees to health hazards.
Recent events (2)
  • — I (O) $5000
  • — Z (S) $7802

1904.40 A

Deleted Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $1951.00 · Current $0.00 Reduced
29 CFR  1904.40(a):The employer did not provide an authorized government representative the records within the four business hours.  OSHA 300s were requested from the employer on April 16, 2021 but were not provided until September 16, 2021.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1951

View PRECISION DRILLING CORPORATION, LP's full OSHA safety record →