Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DRIVEN BY ETERNITY LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DRIVEN BY ETERNITY LLC in 1102 TOWER DRIVE, SUPERIOR, WI 54880 (NAICS 238130). OSHA activity number 345268213.

Watch Driven BY Eternity LLC — free Get an email when a new federal OSHA severe-injury report for Driven BY Eternity LLC is published. One employer, no account, unsubscribe in one click.
Site address
1102 TOWER DRIVE
City
SUPERIOR
State
WI
ZIP
54880
Mailing
1062 ARCHER STREET, MILACA, MN 56353
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.501 B02 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2867.00 Reduced
29 CFR  1926.501(b)(2)(i):Each employee who was constructing a leading edge 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:  (a) Third floor and south intermediate stairway landing below third floor; Employees constructing leading edges above the second level and at heights up to 22 feet above lower levels were not protected from falling.
Recent events (2)
  • — I (S) $2867.2
  • — Z (S) $4096

1926.502 D06 II

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(d)(6)(ii): Snaphooks not designed to be connected to one another were engaged to each other:  (a) Third floor; The snaphook of a Guardian brand 3 ft. single leg external shock lanyard, part no. 01214, serial no. H000050886, was connected with the snaphook of a 3M Protecta brand Rebel series 50 ft. self retracting lifeline cable, model no. 3590500, serial no. 2011163.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1052 C01 I

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $2048.00 Reduced
29 CFR  1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail:  (a) North and south stairways; Multiple stairways comprised of four or more risers and rising more than approximately 63 inches were not equipped with at least one handrail and were used to access various levels.
Recent events (2)
  • — I (S) $2048.2
  • — Z (S) $2926

1926.1052 C01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:  (a) North and south stairways; Stairways comprised of four or more risers and rising more than approximately 63 inches were not equipped with a stairrail system along each unprotected side or edge and were used to access upper levels.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345268213.