Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EA CONSTRUCTION & GENERAL CONTRACTING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of EA CONSTRUCTION & GENERAL CONTRACTING, LLC in 401 SUNSET HOLLOW RD, WEST CHESTER, PA 19380 (NAICS 238160). OSHA activity number 345283543.

Watch EA Construction & General Contracting, LLC — free Get an email when a new federal OSHA severe-injury report for EA Construction & General Contracting, LLC is published. One employer, no account, unsubscribe in one click.
Site address
401 SUNSET HOLLOW RD
City
WEST CHESTER
State
PA
ZIP
19380
Mailing
401 SUNSET HOLLOW RD, WEST CHESTER, PA 19380
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.416 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2575.00 · Current $1545.00 Reduced
29 CFR  1926.416(a)(1):Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means.  a) Jobsite: 445 Corner Ketch Rd, Downingtown, PA - The employer exposed employees installing a new roof on a single story residential home to electrical hazards by permitting them to work in proximity to a service drop line without ensuring its circuit was effectively guarded.  Observed on or about 4/28/2021
Recent events (2)
  • — I (S) $1545
  • — Z (S) $2575

1926.501 B13

Willful Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $30037.00 · Current $18022.00 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):  a) Jobsite: 445 Corner Ketch Rd, Downingtown, PA - The employer did not ensure that employees utilized fall protection during roofing activities. Employees were removing old shingles and installing insulation on a roof, approximately 23 feet above ground level, exposing them to fall hazards.  Observed on or about 4/28/2021.
Recent events (2)
  • — I (W) $18022.2
  • — Z (W) $30037

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345283543.