Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ENGINEERED COMPONENT PRODUCTS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ENGINEERED COMPONENT PRODUCTS, LLC in 35 FORSHAW AVENUE, PLAINVILLE, CT 06062 (NAICS 332721). OSHA activity number 345293245.

Watch Engineered Component Products, LLC — free Get an email when a new federal OSHA severe-injury report for Engineered Component Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
35 FORSHAW AVENUE
City
PLAINVILLE
State
CT
ZIP
06062
Mailing
35 FORSHAW AVENUE, PLAINVILLE, CT 06062
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332721
Employees
7
Ownership type
A

9 citations on file for this inspection.

1910.132 D01

Serious Gravity 10 1 instance 7 exposed
Issued
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR  1910.132(d)(1):The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment.  CNC Machine Area:  On or about May 06, 2021, the employer did not determine the hazards present and what personal protective equipment is needed for handling an injurious corrosive material of distillates (petroleum), hydrotreated heavy naphthenic chemical that is in the Tech Cool 35052CF coolant employees' use weekly. Employees do not wear the necessary personal protective equipment, per the safety data sheet, risking exposure to skin irritation and sensitization and serious eye damage while they transfer the coolant from a 55-gal drum to their respective machines in the CNC Machine Area.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1910.151 C

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR  1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use.  CNC Machine Area:  On or about May 06, 2021, the employer did not ensure that employees regularly using the corrosive coolant Tech Cool 35052CF in the CNC Machine Area were provided with an emergency eyewash station or showers nearby for immediate flushing in the event of an incident.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1910.212 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR  1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Tool Room:  On or about May 06 2021, the employer did not ensure that machine guarding at the point of operation protected employees from injury while operating the OD grinder when the barrier door was open and the rotating parts were still in motion.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1910.242 B

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1755.00 · Current $878.00 Reduced
29 CFR  1910.242(b):Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes:  Tool Room:  On or about May 06, 2021, the employer did not ensure that a chip guard was used on the air compressor while employees removed excess rubber dust on the rubber wheels, exposing employees to flying debris.
Recent events (2)
  • — I (S) $877.5
  • — Z (S) $1755

1910.1200 E01

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $2048.00 Reduced
29 CFR  1910.1200(e)(1):The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.  Company-wide:  On or about May 06, 2021, the employer did not develop a written hazardous communication program to address the hazardous chemicals and material that is stored, used, milled, grinded, and cut in the facility. Some of the chemicals stored in the flammable cabinet included a category 1B carcinogen/category 1 flammable aerosol Rustoleum Spray Paint and a category 1 flammable aerosol/category 2 carcinogen Krylon Spray Paint + Primer located in the Tool Room. Employees also mill A2 Rod steel that contains less than five percent of carbon, lead silicon, and chromium metals.
Recent events (2)
  • — I (S) $2048
  • — Z (S) $4096

1910.1200 F10

Serious Gravity 5 2 instances 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(f)(10): The employer did not ensure that workplace labels or other forms of warnings were prominently displayed on the container or readily available in the work area throughout each work shift.  Tool Room:  On or about May 06, 2021, the employer did not ensure that all containers stored in the flammable cabinet prominently displayed all the labels of the products. Labels on some of the containers were covered with the product preventing employees from clearly determining what it was and what the dangers of handling it was.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G08

Serious Gravity 5 1 instance 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(g)(8):  The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s).  Company-wide:  On or about May 06, 2021, the employer did not ensure that safety data sheets were maintained and accessible at the workplace upon request by employees and authorized government representatives.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 10 1 instance 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(h)(1):Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  Company-Wide:  On or about May 06, 2021, the employer did not provide employees with effective information or training on the hazards present in the facility at the time of the employees initial assignment and thereafter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Other-than-serious 1 instance 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.334(a)(2)(ii):There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:  Tool Room:  On or about May 06, 2021, the employer did not remove from service a damaged extension cord that was plugged into an outlet behind the OD grinder in the Tool Room Area. Employees were exposed weekly to electrical fire hazards caused by damaged extension cords when they used the OD grinder.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View ENGINEERED COMPONENT PRODUCTS, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345293245.