ST CROIX, VI —
OSHA Inspection: SHIHADEH QATTUM
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of SHIHADEH QATTUM in 1C DIAMOND EAST, ST CROIX, VI 00820 (NAICS 236220). OSHA activity number 345315246.
Where did this inspection happen?
- Establishment
- SHIHADEH QATTUM
- Site address
- 1C DIAMOND EAST
- City
- ST CROIX
- State
- VI
- ZIP
- 00820
- Mailing
- PO BOX 6837, CHRISTIANSTED, VI 00823
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 9
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $4096.00 · Current $2458.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling: (a) On or about 5/13/2021, St Croix, VI 00820, the CSHO observed two employees without protective helmets while being exposed to a hazard from falling objects and impact. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
1926.300 A
- Issued
- Abate by
- Penalty
- Initial $4096.00 · Current $2458.00 Reduced
General-duty citation text
29 CFR 1926.300(a): Hand tool(s), power tool(s) were not maintained in a safe condition: (a) On or about 5/13/2021, St Croix, VI 00820, the CSHO observed a De Walt Circular Saw Model no. DW368, Serial no. 176423 with electrical tape on the power cord being used to prevent conductors from being exposed while installing floor panels, exposing employees to electrical shock. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
1926.701 B
- Issued
- Abate by
- Penalty
- Initial $4096.00 · Current $2458.00 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: (a) On or about 5/13/2021, St Croix, VI 00820, the CSHO observed all protruding reinforced steel without rebar caps, exposing employees to impalement hazards. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $4096.00 · Current $2458.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access, and the ladder was not secure at its top to a rigid source: (a) On or about 5/13/2021, St Croix, VI 00820, the CSHO observed a 72" (6 Feet) Aluminum A-Frame portable ladder used by employees (2) to gain access to a lower level that did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access, exposing employees to fall from a ladder. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
1926.1053 B04
- Issued
- Abate by
- Penalty
- Initial $4096.00 · Current $2458.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) On or about 5/13/2021, St Croix, VI 00820, the CSHO observed a 72" (6 Feet) Aluminum A-Frame portable ladder used by employees (2) to gain access to lower level a purpose other than the purpose for which they were designed, exposing employees to fall from a ladder. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
1926.1053 B15
- Issued
- Abate by
- Penalty
- Initial $4096.00 · Current $2458.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: (a) On or about 5/13/2021, St Croix, VI 00820, the CSHO observed a 72" (6 Feet) Aluminum A-Frame portable ladder with a damaged left front side rail used by employees (2) to gain access to a lower level, exposing employees to fall from a ladder. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
1926.1053 B16
- Issued
- Abate by
- Penalty
- Initial $4096.00 · Current $2458.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladder with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. (a) On or about 5/13/2021, St Croix, VI 00820, the CSHO observed a 72" (6 Feet) Aluminum A-Frame portable ladder with a damaged left front side rail used by employees (2) to gain access to a lower level, exposing employees to fall from a ladder. NOTE: Certification and documentation of abatement must be submitted for this citation item as required by CFR 1903.19(c).
Recent events (2)
- — I (S) $2457.6
- — Z (S) $4096
More inspections in this industry (NAICS 236220)
NEWPORT BEACH, CA—2026-07-16
KPRS CONSTRUCTION SERVICES, INC.
CHANDLER, AZ—2026-07-16
SUN STATE BUILDERS
ROCHESTER HILLS, MI—2026-07-16
ICON RESTORATION SERVICES
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
PONCE, PR—2026-07-15
FC CONSTRUCTION LLC
More inspections in VI
CHARLOTTE AMALIE, VI—2026-05-26
VIRGIN ISLANDS EMERGENCY MANAGEMENT AGENCY
ST CROIX, VI—2026-05-06
VI DEPARTMENT OF HEALTH
ST CROIX, VI—2026-04-28
GOV. JUAN F. LUIS HOSPITAL
ST CROIX, VI—2026-04-24
GOV. JUAN F. LUIS HOSPITAL
CHRISTIANSTED, VI—2026-04-24
OFFICE OF DISASTER RECOVERY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345315246.