Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: E-Z LINE PIPE SUPPORT CO,, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of E-Z LINE PIPE SUPPORT CO,, LLC in 21340 HWY 6, MANVEL, TX 77578 (NAICS 332312). OSHA activity number 345365266.

Watch E-Z Line Pipe Support CO,, LLC — free Get an email when a new federal OSHA severe-injury report for E-Z Line Pipe Support CO,, LLC is published. One employer, no account, unsubscribe in one click.
Site address
21340 HWY 6
City
MANVEL
State
TX
ZIP
77578
Mailing
PO BOX 767, MANVEL, TX 77578
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
95
Ownership type
A

5 citations on file for this inspection.

1910.178 Q01

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5969.00 · Current $3581.00 Reduced
29 CFR  1910.178(q)(1):  Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  a) At the rear of the heavy structural building,  a Clark  Deka D-Series forklift, was being operated with a broken seat belt.
Recent events (2)
  • — I (O) $3581
  • — Z (S) $5969

1910.305 B01 II

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $4476.00 · Current $2685.00 Reduced
29 CFR  1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed:  a)  At the heavy structural building, employees used an electrical panel with unused openings, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $2685
  • — Z (S) $4476

1910.334 A02 II

Other-than-serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $4476.00 · Current $2685.00 Reduced
29 CFR  1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service:   a) At the west side of the heavy structural building, the electrical cord of a portable grinder was frayed electrical cord, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $2685
  • — Z (S) $4476

1910.147 C06 I

Other-than-serious 2 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) The employer did not ensure a periodic inspection was conducted of the energy control procedure for a Peddinghaus Anglemaster, model #823-C, serial #57551-000, exposing employees to amputation hazards;    b)  The employer did not ensure a periodic inspection was conducted of the energy control procedure for a MEBA band saw, model #1100 DG, unknown serial number, exposing employees to amputation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1904.41 A02

Other-than-serious 1 instance 165 exposed
Issued
Penalty
Initial $1493.00 · Current $895.00 Reduced
29 CFR  1904.41(a)(2):   The employer failed to electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee no later than the date listed in paragraph(c) of this section of the year after the calendar year covered by the form:  a)  The employer did not electronically submit information from OSHA form 300A for calendar year 2020 by March 2, 2021.
Recent events (2)
  • — I (O) $895
  • — Z (O) $1493

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345365266.