OSHA Inspection: JOSE RODRIGUEZ DBA JC GENERAL CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE RODRIGUEZ DBA JC GENERAL CONSTRUCTION in 1422 GREY AVE., EVANSTON, IL 60201 (NAICS 238170). OSHA activity number 345381271.

Watch Jose Rodriguez DBA JC General Construction — free Get an email when a new federal OSHA severe-injury report for Jose Rodriguez DBA JC General Construction is published. One employer, no account, unsubscribe in one click.
Site address
1422 GREY AVE.
City
EVANSTON
State
IL
ZIP
60201
Mailing
108 RICE AVE., BELLWOOD, IL 60104
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
A

6 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $329.00 · Current $329.00
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   Jose Rodriguez dba JC General Construction, failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number            Item Number                    Abatement Date  01                                         01                                          07/20/2021  01                                         02                                          07/20/2021  01                                         03                                          07/20/2021  01                                         04a                                       07/20/2021  01                                         04b                                       07/20/2021    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $329

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2341.00 · Current $2341.00
29 CFR 1926.100(a):  Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    a) On June 24, 2021, an employee was not wearing protective helmets where there was a possible danger of head injury.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2341

1926.451 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $2926.00
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet above or below the point of access:    a)  On June 24, 2021, employees were not provided with safe access to a pump jack scaffold platform being used at an elevation of approximately 17 feet above the ground.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2926

1926.451 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2926.00 · Current $2926.00
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):   a) On or about June 24, 2021, employees were not protected against contact with energized overhead power lines while performing siding installation work from a pump jack scaffold platform. The overhead power lines consisted of secondary lines having a voltage rating of 120/240 V.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2926

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4096.00 · Current $4096.00
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level.  a)  On June 24, 2021, employees were exposed to the hazard of falling up to approximately 17 feet to the ground, while performing siding installation work from a pump jack scaffold platform.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4096

1926.452 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:   a) On June 24, 2021, pump jack poles used by employees onsite while performing siding installation work were not braced at the bottom to prevent accidental displacement.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $0