Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PLAINVILLE SPECIAL TOOL, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PLAINVILLE SPECIAL TOOL, LLC in 63 NORTH WASHINGTON STREET, PLAINVILLE, CT 06062 (NAICS 332119). OSHA activity number 345387146.

Watch Plainville Special Tool, LLC — free Get an email when a new federal OSHA severe-injury report for Plainville Special Tool, LLC is published. One employer, no account, unsubscribe in one click.
Site address
63 NORTH WASHINGTON STREET
City
PLAINVILLE
State
CT
ZIP
06062
Mailing
63 NORTH WASHINGTON STREET REAR, PLAINVILLE, CT 06062
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332119
Employees
22
Ownership type
A

12 citations on file for this inspection.

1910.133 A03

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2653.00 · Current $1857.00 Reduced
29 CFR  1910.133(a)(3):  The employer did not ensure that each affected employee who wore prescription lenses while engaged in operations that involve eye hazards wore eye protection that incorporates the prescription in its design, or wore eye protection that can be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the protective lenses:  Press Room:  On, or about, June 24, 2021, an employee who was operating Press #7, a Minster partial revolution mechanical power press, was wearing prescription glasses that were not safety glasses.
Recent events (2)
  • — I (S) $1857.1
  • — Z (S) $2653

1910.212 A01

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1691.00 · Current $1184.00 Reduced
29 CFR  1910.212(a)(1):Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by the unused portion of a saw blade:  Tool Room:  On, or about, June 30, 2021, the guard provided for the unused portion of the blade on the Grob vertical band saw did not protect employees from inadvertent contact with the unused portion of the blade above the cutting area.
Recent events (2)
  • — I (S) $1183.7
  • — Z (S) $1691

1910.217 C02 I A

Serious Gravity 5 2 instances 4 exposed
Issued
Penalty
Initial $3316.00 · Current $2321.00 Reduced
29 CFR  1910.217(c)(2)(i)(a):  Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s):  Press Room: On, or about, June 24, 2021, barrier guards on the following straight-sided mechanical power presses were adjusted to allow entry into the die area:  A.	Press #1, Minster. B.	Press #4, Verson.
Recent events (2)
  • — I (S) $2321.2
  • — Z (S) $3316

1910.217 E01 I A

Serious Gravity 5 1 instance 10 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.217(e)(1)(i)(A):  Periodic and regular inspections of each power press were not conducted to ensure that all of its parts, auxiliary equipment, and safeguards, including clutch/brake mechanism, anti-repeat feature, and single-stroke mechanism, are in safe operating condition and adjustment:  Plant:  On, or about, July 7, 2021, mechanical power presses were not subject to periodic, documented inspections.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 F03

Serious Gravity 1 1 instance 3 exposed
Issued
Penalty
Initial $1691.00 · Current $1184.00 Reduced
29 CFR  1910.217(f)(3):Floors surrounding mechanical power press(es) were not kept in good condition and free from obstructions, grease, oil or water:  Press Room:  On, or about, June 24, 2021, boxes, barrels, shelving and other material had collected in the work area for Press #7, a Minster partial revolution mechanical power press.
Recent events (2)
  • — I (S) $1183.7
  • — Z (S) $1691

1910.304 G05

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $2255.00 · Current $1579.00 Reduced
29 CFR  1910.304(g)(5):  The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  Press Room:  On, or about, June 24, 2021, the ground pin was missing from a portable light fixture used at Press #7, a Minster partial revolution power press.
Recent events (2)
  • — I (S) $1578.5
  • — Z (S) $2255

1910.305 G01 IV C

Serious Gravity 5 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(C):  Flexible cords and cables were used where run through doorways, windows, or similar openings:  Press Room:  On, or about, June 24, 2021, an extension cord was run through an interior window opening to energize a portable light fixture used at Press #7, a Minster partial revolution mechanical power press.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.41 A02

Other-than-serious 1 instance 21 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1904.41(a)(2):  The establishment had 20 or more but fewer than 250 employees at any time during the previous calendar year, and the establishment was classified as an industry listed in appendix A to subpart E of this part, but did not electronically submit information from OSHA 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee.  The employer did not submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form:  (a) Plainville Special Tool, LLC, 63 North Washington Street, Plainville, Connecticut:  On, or about, July 7, 2021, and times prior thereto, the employer failed to electronically submit information from their OSHA Form 300A Summary of Work-Related Injuries and Illnesses for 2020 or equivalent on or before March 2, 2021.  The establishment employed 21 employees and was classified under NAICS 332119 during calendar year 2020.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(6)(i):  The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  Company:  On, or about, July 7, 2021, the employer's lockout/tagout program had not been subject to a periodic, documented review for approximately ten years.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.215 B09

Other-than-serious 1 instance 3 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.215(b)(9):  Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:  Tool Room:  On, or about, June 30, 2021, the Dayton pedestal grinder was not provided with a tongue guard on either side.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.217 B12

Other-than-serious 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.217(b)(12):  All pressure vessels used in conjunction with power presses did not conform to the American Society of Mechanical Engineers Code for Pressure Vessels, 1968 Edition:  Ref. UG-125  Press Room:  On, or about, June 24, 2021, air receiver tanks on the following mechanical power presses were not provided with pressure relief valves:  A.	Press #15, Walsh. B.	Press #12, V&O.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.242 B

Other-than-serious 3 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.242(b):  Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  In the following locations, compressed air nozzles used for cleaning were measured to be greater than 30 p.s.i., dead-ended:  A.	Press Room:  On, or about, June 24, 2021, the compressed air nozzle provided at Press #2, a Minster partial revolution power press. B.	Welding Area:  On, or about June 30, 2021, the compressed air nozzles provided at: 1.	#2 resistance welder 2.	Thompson resistance welder.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345387146.