OSHA Inspection: KME AMERICA MARINE TUBE & FITTING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KME AMERICA MARINE TUBE & FITTING, INC. in 3440 EVERGREEN AVENUE, JACKSONVILLE, FL 32206 (NAICS 332919). OSHA activity number 345391262.

Watch KME America Marine Tube & Fitting, INC. — free Get an email when a new federal OSHA severe-injury report for KME America Marine Tube & Fitting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3440 EVERGREEN AVENUE
City
JACKSONVILLE
State
FL
ZIP
32206
Mailing
3440 EVERGREEN AVENUE, JACKSONVILLE, FL 32206
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332919
Employees
89
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $9557.00 · Current $5734.00 Reduced
29 CFR  OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm, including injuries from crushed-by and struck-by hazards:  a. At this facility located at 3440 Evergreen Avenue, Jacksonville, Florida: On or about June 29, 2021, employees operated power industrial trucks (forklifts) that had the potential to tip-over, thereby exposing employees to crushed-by and struck-by hazards.
Recent events (2)
  • — I (S) $5734.2
  • — Z (S) $9557

1910.110 F02 I

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $6827.00 · Current $4096.00 Reduced
29 CFR  1910.110(f)(2)(i): Containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering from unauthorized persons:   a. At this facility, located at 3440 Evergreen Avenue, in Jacksonville, Florida: On or about June 29, 2021, the employer exposed employees to fire and explosion hazards, in that, four LP gas cylinders were stored free standing outside the cage and were not protected from physical damage from forklift traffic.
Recent events (2)
  • — I (S) $4096.2
  • — Z (S) $6827

1910.253 B04 III

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $6827.00 · Current $4096.00 Reduced
29 CFR  1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  a. At the facility  located at 3440 Evergreen Avenue in Jacksonville, Florida: On or about June 29, 2021, the employer exposed employees to fire and explosion hazards, in that  four (4) oxygen cylinders were stored directly with two (2) fuel-gas (acetylene) cylinders, without any form of separation.
Recent events (2)
  • — I (S) $4096.2
  • — Z (S) $6827