Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ED BOZARTH CHEVROLET COMPANY, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ED BOZARTH CHEVROLET COMPANY, INC. in 2001 SOUTH HAVANA STREET, AURORA, CO 80014 (NAICS 811111). OSHA activity number 345401855.

Watch ED Bozarth Chevrolet Company, INC. — free Get an email when a new federal OSHA severe-injury report for ED Bozarth Chevrolet Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2001 SOUTH HAVANA STREET
City
AURORA
State
CO
ZIP
80014
Mailing
2001 SOUTH HAVANA STREET, AURORA, CO 80014
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
88
Ownership type
A

5 citations on file for this inspection.

1910.134 G01 I A

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $5266.00 · Current $2634.00 Reduced
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  (a) On or about July 6, 2021, and at times prior, employees who were required to wear tight-fitting respirators in the collision and paint department, had facial hair between the skin and seal of the tight fitting respirator.   Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2634
  • — Z (S) $5266

1910.151 C

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5266.00 · Current $2633.00 Reduced
29 CFR  1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   (a)  On or about July 6, 2021, and at times prior, the employer did not ensure that employees working with AutoMagic Magnificient Tire and Wheel Cleaner, a liquid mixture containing sodium hydroxide, an eye and skin corrosive, had access to an eyewash where the eyewash station was taped up and the water supply was turned off which prevented its use.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2633
  • — Z (S) $5266

1910.212 A01

Serious Gravity 1 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $5266.00 · Current $2633.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a)  On or about July 6, 2021, and at times prior, the employer exposed employees to flying chips and debris in that two brake lathes, located in the automotive shop area, were not guarded at the point of operation:      1)  Ammco brake lathe, serial number illegible      2)  Brake lathe, brand and serial number illegible  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2633
  • — Z (S) $5266

1910.106 E09 III

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:   (a)  On or about July 6, 2021, and at times prior, employees were exposed to fire hazards because trash from the paint mixing room was stored in an open plastic trash can instead of a closed metal receptacle.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 14 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   (a)  On or about July 6, 2021, and at times prior, the employer did not maintain a clear distance of three feet in front of the circuit breaker panels, located on the south wall in the collision center, to provide access for emergency maintenance.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345401855.