Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SPECKS FABRICATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPECKS FABRICATION in 1069 LOUISIANA 3185, THIBODAUX, LA 70301 (NAICS 332312). OSHA activity number 345405112.

Watch Specks Fabrication — free Get an email when a new federal OSHA severe-injury report for Specks Fabrication is published. One employer, no account, unsubscribe in one click.
Establishment
SPECKS FABRICATION
Site address
1069 LOUISIANA 3185
City
THIBODAUX
State
LA
ZIP
70301
Mailing
1069 LOUISIANA 3185, THIBODAUX, LA 70301
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
36
Ownership type
A

3 citations on file for this inspection.

1910.212 A05

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5461.00 · Current $5461.00
29 CFR  1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:    a) On or about July 6, 2021, in the fabrication shop, the guard over the inlet of an air fan blower blade had openings of two inches.
Recent events (2)
  • — I (O) $5461
  • — Z (S) $5461

1910.157 C01

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   a) On or about July 6, 2021, in the Turbo Pump Building, a fire extinguisher was not present at a visibly marked location of a fire extinguisher mount.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F02

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(f)(2):Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:   a) On or about July 6, 2021, in the Turbo Pump Building, an electrical panel did not have each individual breaker labeled for its purpose.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

OXYCHEM