ROSELLE, IL —
OSHA Inspection: JG CONSTRUCTION & ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JG CONSTRUCTION & ROOFING, INC. in 6N171 GARY AVE., ROSELLE, IL 60172 (NAICS 238160). OSHA activity number 345407555.
Where did this inspection happen?
- Establishment
- JG CONSTRUCTION & ROOFING, INC.
- Site address
- 6N171 GARY AVE.
- City
- ROSELLE
- State
- IL
- ZIP
- 60172
- Mailing
- 1048 N. PARKSIDE, CHICAGO, IL 60651
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.502 D16 III
- Issued
- Abate by
- Penalty
- Initial $2341.00 · Current $1300.00 Reduced
General-duty citation text
29 CFR 1926.502(d)(16)(iii):Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: On or about July 8, 2021 personal fall arrest systems were not rigged to limit the fall distance to 6 feet or less, exposing employees to injuries from falls of approximately 12.5 feet. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $1300
- — Z (S) $2341
1926.503 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. On or about July 8, 2021 the employer did not verify training compliance for employees performing commercial construction operations at heights exceeding six feet. Abatement certification is required of this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source