OSHA Inspection: DONE 1NCE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DONE 1NCE, INC. in 200 COLE ST. BLDG.: 8, PRINCETON, TX 75407 (NAICS 238130). OSHA activity number 345417950.

Watch Done 1NCE, INC. — free Get an email when a new federal OSHA severe-injury report for Done 1NCE, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DONE 1NCE, INC.
Site address
200 COLE ST. BLDG.: 8
City
PRINCETON
State
TX
ZIP
75407
Mailing
1334 CR 2726, CADDO MILLS, TX 75135
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
30
Ownership type
A

2 citations on file for this inspection.

1926.502 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6827.00 · Current $6827.00
29 CFR  1926.502(b)(1):The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:  (a) On or about July 14, 2021, an employee working while standing on a second floor balcony was not protected from a fall hazard of approximately eleven (11) feet or more in that the top rail was not within 39-45 inches above the balconies floor.
Recent events (1)
  • — Z (S) $6827

1926.502 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high:  (a) On or about July 14, 2021, an employee working while standing on a second floor balcony was not protected from a fall hazard of approximately eleven (11) feet or more in that no intermediate structural member had been installed between the top edge of the guardrail system and the working surface.